Stylos 2 All Weather
INSTALLATION GUIDE (EN)
i s e o . c o m
Non contractual document. Subject to change. Cod. 60000STY2CV00.7 - 31/03/2021
Stylos 2 Credential Reader All Weather Inst. guide (EN) - © 2021 Iseo Serrature S.p.a. - www.iseo.com
TECHNICAL DATA
Power Supply: 8÷30 VDC 3W MAX
RFID: frequecy 13,553 - 13,567 MHz, maximum magnetic field: 0,89 µA/m (measured at 10m at the
maximum power capacity).
Only for devices with on-board Bluetooth radio: frequecy 2,40 - 2,45 GHz, maximum power: 5,25 mW.
Operating temperature: -20°C + 60°C
3V
Lithium
Lithium Battery
CR2032
CR2032 - 3V
Risk of explosion if the battery is replaced with an incorrect type.
Dispose of batteries according to your local environmental laws and guidelines.
Battery replacement must be carried out by qualified technical staff.
For the replacement battery procedure, read the user manual available at app.iseo.com.
2. DISASSEMBLING INDOOR MODULE
PUSH
PUSH
1
PULL UP
2
PULL UP
3.1 STAND-ALONE GATE ELECTRICAL CONNECTIONS
Power supply: 8 ÷30 VDC 3W
MAX
Minimum/maximum cross-section
of the cables is:
0.20÷1.5
mm²
(24÷15AWG).
Do not extend the cable supplied
with the external device (5 mt).
Install the internal module only in
a protected area.
LEGEND:
S1 = Programming button
JP 0/2/4/6 = Bus Address Jumpers
BUS
JP
JP
JP
JP
FUNCTION
6
4
2
0
ADDRESS
ADDRESS 0 =
(Master)
(slave)
ADDRESS 2 =
(slave)
ADDRESS 4 =
(slave)
ADDRESS 6 =
Iseo Serrature s.p.a
®
Via San Girolamo 13
25055 Pisogne (BS)
ITALY
Tel. +39 0364 8821
ELECTRONIC SUPPORT SERVICE
iseozero1.com
Side view
Back view
GREEN + GREY + SHIELD (or black)
RED
WHITE
BROWN
YELLOW
PINK
BLUE
LOCKBUS
(Communication Channel)
POSITIVE (+) Power Supply
NEGATIVE (-) GND
Control Unit
1
Circuit View
J2.
J2.
J2.
J2.
2
1
2
3
4
3
4
JPS
5
JP
JP
JP
JP
6
4
2
0
JP
JP
6
4
S1
BUS
ADDRESS
WARNINGS
Read this manual prior to use the device in order to ensure a safe and proper use.
Preserve this manual as future reference.
The installation and maintanance of the device must be carried out by qualified technical staff, adequately
trained by ISEO.
The instructions should be carefully followed during installation. These instructions and any maintenance
instructions should be passed on by the installer to the user.
No modifications of any kind are permitted, except for those described in these instructions.
The product must be destined only for the use for which it is expressly designed and therefore as a
credential reader for civil and industrial locations. Any other use is considered improper and dangerous.
The electrical connection must be made according to the constructor's instructions and respecting the
regulations in force.
In the event of a failure and/or poor operation, remove the power supply using the main switch and do not
tamper with it. For all repairs, exclusively contact a technical assistance center authorized by the constructor.
Disconnect the power supply before carrying out any technical service that involves opening or accessing
the internal parts of the product.
1. VERSIONS AND DIMENSIONS
Credential reader
(outdoor module)
A = 47,5mm
B = 17,5mm
C = 130mm
This guide includes instruction to configure the Stylos as Stand-Alone gate or as
Reader/Validator, connected to Atlas. Refer to the proper section.
3. STAND-ALONE GATE SETTING
Control Unit
Circuit View
J2.
J2.
J2.
J2.
1
2
3
JPS
JP
JP
JP
JP
6
4
2
0
4. READER/VALIDATOR SETTING
Control Unit
Circuit View
J2.
J2.
J2.
1
2
3
JPS
JP
JP
JP
JP
6
4
2
0
J2.
J2.
J2.
J2.
1
2
3
4
JPS
JP
JP
2
0
S1
Control unit
(indoor module)
A = 45mm
B = 19,3mm
C = 113mm
Only to set the Stylos 2 All Weather to be used as
Stand-Alone gate, you have to close, by a wire,
holes 2 and 3 of the green connector shown in the
picture.
1
2
Fit the wire when the
3
Stylos is OFF.
4
4
5
S1
Stylos as Stand-Alone gate = Address 0 (Master)
Stylos as Reader/Validator = Address 1
J2.
4
S1
For more information about Stylos and Atlas, refer to
the Atlas Installation Manual available at:
app.iseo.com.
EC Declarations of conformity available at:
https://www.iseo.com/it/en/download
Spacer for wall
installation
A = 40mm
B = 10mm
C = 125mm