7. ELECTRONICS UNIT
7.1. Interface
1
2
ELEMENT
Red LED
Green LED
Screen
7.2. Switching on
When connecting the electronics unit to a power supply:
After about a minute, production starts automatically, according to the setpoint displayed on the screen.
If the electronics unit is powered off (screen off, red LED on):
Press twice on the upper control key. After about a minute, production starts automatically, according to the
setpoint displayed on the screen.
7.3. Switching off
Set the production setpoint to 00 using the top key (no confirmation required): after a few seconds, the screen turns
off and the red LED comes on.
The internal fan in the electronics unit may continue running as long as the unit is powered on.
7.4. Salt value adjustment (ULTRA LOW SALT)
The nominal salt level should be adjusted to approximately 1 g/litre. It must not fall below 0.5 g/litre.
The adjustment is done manually, and the measurement is done using independent means (strip or measuring device).
Do not take into account the chlorine values given in the maintenance manual.
7.5. Adjustment of the reversal frequency of the current supplying the cell (optional)
I
Reversing the flow aims to prevent limescale deposits on the cell. The frequency at which flow is reversed
must be correctly set following the table below in order to ensure that the cell continues to operate correctly over
the long term.
Possible settings: 02, 04, 06, 08, 10, 12, 14, 16 (hours).
Default setting: 04.
Non-binding images
3
STATUS
Continuously on
Flashing
Continuously on
Default display
Flashing display
Steady display
1 : Red LED
2 : Green LED
4
3 : Screen
4 : Control keys
Electronics unit powered off
Production in progress
Production setpoint
Information awaiting validation, or alarm
Confirmed information
MEANING
Alarm activated
9