HQ EL-PIR70 Manual Del Uso página 3

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
Technical specifications
power supply: 220-240VAC
power frequency: 50/60Hz
Installation sit: indoors, wall/ceiling mounting
HF system: 5.8GHz CW radar, ISM band
transmission power: <10mW
rated load:1200W: 220-240VAC
detection angle: 360°, 160°
reach:1-8m (dia.), adjustable
time setting: 5sec to 15min
light control: 2~2000LUX
Connection illumination
connect N,L with power; connect N, L' with load
Reach setting (sensitivity)
Reach is the term used to describe the diameter of
the more or less circular detection zone produced
on the ground after mounting the sensor at a height
of 2.5m, turn the reach control fully anticlockwise
1-8 dia
to select minimum reach (approx.1 m dia), and fully
clockwise to select maximum reach (approx. 8m dia).
Time setting
The light can be set to stay ON for any period of time between approx. 5sec
(turn fully anticlockwise) and a maximum of 15min (turn fully clockwise).
Any movement detected before this time elapse will re-start the timer. It is
recommended to select the shortest time for adjusting the detection zone
5sec~15min
and for performing the walk test.
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start
detecting movement again. The light will only switch on in response to movement
once this period has elapsed.
Light-control setting
The chosen light response threshold can be infinitely from approx. 2-
2000lux. Turn it fully anti-clockwise to select dusk- to-dawn operation at
about 2 lux. Turn it fully clockwise to select daylight operation at about
2000lux. The knob must be turned fully clockwise when adjusting the
2~2000LUX
detection zone and performing the walk test in daylight.
2
Tabla de contenido