Non-ductedrecirculation
Configuration
1. Adjust
the width of the flue mounting
bracket
to equal
the inside
width of
decorative
flue.
insert
and
tighten
mounting screws to hold bracket width.
2. Use mounting screws and wall anchors to
secure fBue mounting
bracket
to the
ceiling as shown.
3. Turn upper flue section upside down so
air vents are at the top. Slide upper flue
section into mower ftue section.
4. Connect
the non-ducted
recirculation
plenum to the upper flue section with (4)
flat-head screws (supplied).
5. Install the reduction on the discharge collar.
6. Measure the distance from the top of the
reduction to the ceiling. Cut a iength of 5"
round
metal
duct 5" shorter than this
dimension.
7. Fit duct section
over the non-ducted
recirculation plenum. For best fit, make sure
duct seam is toward the front.
8. Set duct/flue assembly on hood with top
tilted away from wall Reach around fiue
to engage bottom of duct with discharge
collar on hood. TiNtfHJe up against wall.
Duct
seam
can be cut to length
if
necessary.
9. Extend the upper flue to the ceiling and
secure with two mounting screws.
FLUE MOUNTING
BRACKET
MOUNTENG SCREWS
MOUNTING SCREWS
FASTEN FLUE TO
UPPER BRACKET
WiTH MOUNTING
SCREWS