4. Pour ALL of the provided media (fire ice or lava rock) into the burner pan. The burner MUST
be completely covered to ensure the appliance functions properly and safely. Remove any lava
rocks or fire ice on top of the ignition well. See figure4.
Figure 4
5. Slide the tank drawer out, place the LP tank (not provided) in the drawer and secure it with
the chain as shown in Figure 5. With the BLACK lever in the "down/off" position as shown in
Figure 6, firmly push the regulator onto the tank valve. To open the valve, lift the BLACK lever
and turn the handle 90° clockwise to the "ON" position. See Figure 7. Apply a solution of soapy
water to the tank-regulator connection and to the valve-hose connection to check for leaks. If
soap bubbles continue to form, the connection has a leak. If a leak is found, close the tank valve
and tighten all connections. NEVER USE A FLAME TO CHECK FOR LEAKS. In case of gas
leakage; for instance, in the event of gas leakage, the appliance shall not be used or if alight,
the gas supply shall be shut off and the appliance shall be investigated and rectified before it is
used again. To remove the regulator, turn the Black Lever counterclockwise and press straight
in. See Figure 8.