Mounting Instructions
Rain Bird Pedestal (LXMMPED)
Your pedestal can be used for indoor or outdoor
installations of Rain Bird controllers. The PED kit
includes only the pedestal, which is optimized for
use with the Rain Bird controller cabinet (LXMM).
The cabinet can be purchased as a standalone
product and a kit including a pedestal and a cabinet
(LXMMPED) is also available. The instructions below
detail installation of the pedestal only.
The pedestal should be mounted on a level con-
crete base with the top of the base at least 2" above
ground level. We suggest construction of a base of
at least 9" width x 18" length x 11" depth (23 x 46 x
28 cm). Please read all instructions below prior to
construction of the base! A single base can be used
for multiple pedestals if desired. If multiple pedes-
tals will be mounted on a single concrete base, at
least 5" (12.7 cm) space in every direction should be
allowed between each pedestal.
Pedestal Mounting Instructions:
1. Prior to pouring the concrete for the base, position a sweep elbow of maximum 1.5" (3.81 cm) width and additional sweep
elbows of maximum ½" (1.27 cm) width for power and/or modem connections if needed (see Figure 1).
2. It is very important to ensure the sweep elbows terminate inside the footprint of the pedestal base, which is marked as the
shaded area of the included positioning template. Sweep elbows for power should be installed to the left side of the base
and elbows for other wiring to the right (see Figure 2).
2.8
2.3
ESP-LX Modular Pedestal and Controller Cabinet - Mounting Instructions
Pedestal
Positioning Template
Anchor Bolt
4
AC line input
conduit
(class 1 wiring)
Anchor Bolt
18.0
Figure 2
Controller Cabinet Mounting Instructions (LXMM)
½" conduit for 117 volt line input wires
and pump start wires (class 1 wiring)
Figure 1
Anchor Bolt
8.6
Valve control wires
phone access line
conduit (class 2 wiring)
Anchor Bolt
13.5
Up to 1½" conduit for valve
control wires (class 2 wiring)
½" conduit for phone
access line input (optional)
(4x) anchor bolts
9.0
3.5
2.7
2.7
2.8