Installing Cabinetry Over Your Jenn-Air Grill
*A = 30² (76.2 cm) minimum vertical clearance between
cooking surface and construction above the
appliance.
*B = 13² (33.02 cm) maximum depth of cabinets installed
above cooking top.
*
To eliminate associated potential hazards such as
reaching over open flames, avoid use of cabinets above
cooktop for storage space.
Cabinets Above Cooking Top
Maximum depth of cabinets installed above cooking top is
13 inches.
CAUTION:
SOME CABINETS AND BUILDING
MATERIALS ARE NOT DESIGNED TO WITHSTAND
THE HEAT PRODUCED BY THE NORMAL SAFE
OPERATION OF A LISTED APPLIANCE.
DISCOLORATION OR DAMAGE, SUCH AS
DELAMINA- TION, MAY OCCUR.
WARNING
NOTE: THE FIGURE MAY NOT ACCURATELY REPRESENT
YOUR RANGE OR COOKTOP; HOWEVER, THIS WARNING
APPLIES TO ALL GAS COOKING PRODUCTS.
Dotted lines
indicate
range hood
construction
THIS PRODUCT SHOULD NOT
BE INSTALLED BELOW A
VENTILATION TYPE HOOD
SYSTEM THAT DIRECTS AIR
IN A DOWNWARD DIRECTION.
(SEE FIGURE)
THESE SYSTEMS MAY CAUSE
IGNITION AND COMBUSTION
PROBLEMS WITH THE GAS
BURNERS RESULTING IN
PERSONAL INJURY AND MAY
AFFECT THE COOKING
PERFORMANCE OF THE UNIT.

Installation Of Appliance

Follow accompanying ducting instructions carefully.
This appliance is designed to always be vented outdoors.
The Countertop Cutout, Cabinet Front Cutout and Duct
Opening should be prepared according to the illustrations
on pages 1 and 2.
The installation of this appliance must conform with local
codes or, in the absence of local codes, with the latest
edition of the National Fuel Gas Code, ANSI Z223.1 USA
or current CAN/CGA-B149 INSTALLATION CODE.
In The Commonwealth Of Massachusetts
This product must be installed by a licensed plumber or
gas fitter when installed within the Commonwealth of
Massachusetts.
A "T" handle type manual gas valve must be installed in
the gas supply line to this appliance.
A flexible gas connector, when used, must not exceed a
length of three (3) feet / 36 inches.
The electrical supply required is
110/120 Volt, A.C., 15 amp, 60
Hz. This appliance is equipped
with a grounded tpe power cord.
A grounded outlet must be pro-
vided. It is recommended, for
convenience, this outlet be lo-
cated in the area shown in the
shaded illustration (see figure 2).
User may experience occasional circuit tripping if Ground
Fault Circuit Interrupter (GFCI) outlet or breaker is in use.
This appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the latest edition of the
National Electrical Code ANSI/NFPA No. 70 USA or
current CSA STANDARD C22.1 Canadian Electrical Code
part 1.
Warranty is void on JENN-AIR equipment installed other
than as recommended by manufacturer. Recommended
wall caps and transitions must be utilized for proper
operation and installation.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS
APPLIANCE
THREE-PRONG GROUNDING PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD AND
SHOULD
BE
PLUGGED
PROPERLY GROUNDED RECEPTACLE. DO NOT
CUT OR REMOVE THE GROUNDING PRONG FROM
THIS PLUG.
2
Cabinet Bottom
Figure 2
CAUTION
WARNING
IS
EQUIPPED
WITH
DIRECTLY
INTO
A
A
Tabla de contenido
loading

Este manual también es adecuado para:

Jgd8345 serie

Tabla de contenido