Akron Brass Navigator Pro Instrucciones De Instalación, Funcionamiento Y Mantenimiento página 7

Controlador de válvulas
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Style 9323 Wiring:
Display Connector (Mates with Deutsch Connector DT06-08SA-EP08 & W8S)
PIN
Function
1
NO FUNCTION
2
CAN HIGH
3
Ground OUT
4
Ground IN
5
Battery Voltage IN
6
Battery Voltage Out
7
CAN LOW
8
NO FUNCTION
NOTE: Pins 4 and 5 are the power being supplied to the Display . Pins 3 and 6 can be used to supply power to the next display in line or can be used to
power the motor driver on the valve (connect to pins 3 and 4 of the 6 pin Display connector on the valve). If pins 3 and 6 are used to supply power to the
next display, separate power will need to be supplied to the motor driver on the valve .
Valve Wiring:
1
2
Motor
5
6
7
8
4
3
2
1
1
2
3
4
2
1
3
4
Flow
Pressure
Display
SCALE 3.000
4
5
6
3
2
1