MAGNUM Sol
Dear customer,
Congratulations on the purchase of this MAGNUM product. The MAGNUM Sol panels are
manufactured from high quality, durable materials. To guarantee that your product functions
optimally there are a few points of attention which are described in the Installation Instructions. We
can only offer you the full guarantee if the MAGNUM Sol is correctly installed in accordance with
the Installation Instructions. Carefully read the instructions prior to installation and ensure that you
have the correct tools and materials. The electrical installation must be carried out by a qualified
electrician in accordance with IEE Regulations. Visit our website for your local MAGNUM supplier,
technical helpdesk or more information and other products at magnumheating.com
Technical information
Art.nr.
Type
600331
Sol 300
600661
Sol 600
Class
: IP44
Colour
: RAL 9016
Area of use
The MAGNUM Sol heating panel is intended
for the heating of rooms requiring free walls.
The panel can be used for complete heating,
or as an additional heater (e.g. over a reception
desk or other work place). There are two ratings:
300W and 600W. The heating panel provides
mainly radiation heating. This implies that to
obtain the same experienced temperature it is
possible to reduce the air temperature in the
room, which saves energy. Because of the low
surface temperature, max 110°C, the heating
panel is suitable for rooms with relatively low
ceiling height. Thanks to the location, the
panel is protected from any physical contact or
damage. There is no risk of being burned.
Design
The MAGNUM Sol heating panels are available
for 230V and are approved by KEMA for two
applications:
- Ceiling mounting: Heating cassette is directly
mount to the ceiling using the included
mounting brackets.
- Flush ceiling mounting: Heating cassette is
intended as a lay-in panel for exposed grid.
6
Output
Voltage Amps
300W
230V
1.30
600W
230V
2.61
Max surface temp. Measurements
110 0C
590 x 590mm
110 0C
1190 x 590mm
MAGNUM Sol Heating cassettes Installation
Manual
1. Points of attention
1. The heater(s) should only be wired by a
competent electrician, and in accordance with
existing national regulations. The appliance
should be preceded by an all pole switch in
accordance with existing regulations (not
applicable to versions with a cord and plug).
2. Mounting height above floor shall be at least
1,8 m, lateral distance to wall shall be at least 50
mm. (See fig 1)
3. One or more units have to be connected to
power line with a differential circuit breaker
rated at 30 mA. The cable section has to be at
least 1,5 mm2.
4. Units with cable and plug can be
interconnected using appropriate connection
materials.
5. The maximum power in interconnection is
2100W. If the units are to be extra insulated,
then this insulation must not exceed a value of
R=5 m2K/W.
6. The appliance is not to be used by children
or persons with reduced physical, sensory
or mental capabilities, or lack of experience
and knowledge, unless they have been given
supervision or instruction
7. Children being supervised not to play with
the appliance.
8. Allow disconnection of the appliance after
installation, by accessible plug or a switch in the
Weight
5 kg
10,1 kg
loading