Vimar ELVOX ZD16 Manual Para El Conexionado Y El Uso página 3

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
1. GENERAL DESCRIPTION
L'Art. ZD16 is a proximity reader with data output in Wiegand or Dataclock format. It can be connected both to ELVOX serie
ZD access control units and to other units that accept the data format generated by the reader.
L'Art. ZD16 works with the proximity badges and tags. All the electronic components and the antenna are assembled in an en-
tirely sealed container with high resistance to atmospheric agents (IP67). The reader is equipped with a two-colour red/green
LED and a buzzer to indicate the various functioning phases. To install, assemble the reader and connect the cable to the
access control unit in accordance with the instructions shown below.
2. TECHNICAL FEATURES
Power supply
Average absorption
Reading technology
Reading range
Signalling
Connection distance to the host
Insulation class
3. CONNECTIONS
RED
GRAY or BLACK
GREEN
WHITE
ORANGE
CYAN or BLUE
YELLOW
BROWN
VIOLET
PINK
4. FUNCTIONING
• Power up the reader. The buzzer beeps once and the led turns on (red)
• Place a badge, a tag or a double technology transmitter in front of the reader: the buzzer sounds, the LED turns into green and
the code of the badge is output at DATA0-DATA1 in Wiegand 30 bit format. The LED remains green and the PRESENCE line
(PINK wire) goes low (0V) as long as the badge is hold in the field of the reader. The standby status of the PRESENCE line is
high (5V)
5. DATA FORMAT
If the MODE input (BROWN wire) is left unconnected or tied to 5 Vdc the output data format is Wiegand. If the MODE input is
connected to GROUND the output data format is DataClock.
While in Wiegand mode (BROWN wire unconnected or tied to 5 Vdc), if the WIEGAND FORMAT input (YELLOW wire) is left
unconnected or tied to 5 Vdc, the data format at DATA0-DATA1 is 30-bit Wiegand. If the WFMT input is connected to GROUND,
the data format at DATA0-DATA1 is 26-bit Wiegand.
6. LED DRIVING
If the ORANGE and CYAN wires are left unconnected or tied to 5 Vdc the status of the led is driven by the reader itself.
If one or both of the ORANGE and CYAN wires are connected to GROUND, the status of the LED changes as follows:
ORANGE wire
GROUND
GROUND
5 Vdc or floating
7. ASSEMBLY INSTRUCTIONS
• To assemble the reader, drill two 2.5 mm. holes in the support bracket for the fixing screws and one 6 mm diameter hole for
the cable (fig. 1). Place an insulating gasket around the hole. Hook-up the interface cable from the reader to the access con-
trol station and mount the reader using screws with a max. diameter of 3 mm (fig. 2).
• Fix the cover to the base, pressing until the hooks click into place (fig. 3).
• Connect the reader to the host following the instructions in the table below and in the central unit installation manual.
Keep in mind that installing the reader on metal surfaces could decrease the reading distance.!
ZD16
RED
BLACK
GREEN
WHITE
GB
12 Vdc
20 mA
Proximity - 125 KHz
8 cm
Bicolour led (red/green), buzzer
100 meters max.
IP 67
12 Vdc
GROUND
DATA0
DATA1
Red LED driving
Green led driving
WIEGAND FORMAT
MODE
Not used
PRESENCE
CYAN wire
GROUND
5 Vdc or floating
GROUND
ZD15/3/4/5/10
+12 Vdc
+12
GROUND
GND
DATA 0
D0.1
DATA 1
D1.1
LED status
OFF
RED
GREEN
ZD15/3/4/5/10
+12
GND
D0.2
D1.2
ZD15/5/10
ZD15/5/10
+12
+12
GND
GND
D0.3
D0.4
D1.3
D1.4
1