INSTALLATION INSTRUCTIONS

Connecting the water lines

1
Check the rubber seals on both sides of the hose.
- Insert a rubber seal into the threaded fittings on
each hose to prevent leaking.
Rubber seal
Water hose
(To water inlet on the
washing machine)
2
Connect the water supply hoses to the HOT and
COLD water faucets tightly by hand and then tighten
another 2/3 turn with pliers.
-
Connect the blue hose to a cold water faucet
and the red hose to a hot water faucet.
WARNING
y Do not overtighten. Damage to the coupling can
result.
3
After connecting inlet hose to water faucets, turn
on the water faucets to flush out foreign substances
(dirt, sand or sawdust) in the water lines. Let water
drain into a bucket, and check the water temperature.
Rubber seal
Water hose
(To faucet)
4
Connect the hoses to the water inlets tightly by hand
and then tighten another 2/3 turn with pliers.
- Connect the blue hose to the cold water inlet and
the red hose to the hot water inlet.
Cold
water
inlet
WARNING
y Do not overtighten the hoses. Overtightening
can damage the valves resulting in leaking and
property damage.
5
Check for leaks by turning on the faucets.
- If water leaks, check steps 1 to 4 again.
NOTE
For your safety, and for extended product life, use
y
only authorized components. The manufacturer
is not responsible for product malfunction
or accidents caused by the use of separately
purchased unauthorized parts.
Use new hoses when you install the washing
y
machine. Do not reuse old hoses. Use only the
inlet hoses provided with the washer. LG does not
recommend the use of aftermarket hoses.
Periodically check the hoses for cracks, leaks and
y
wear, and replace the hoses every 5 years.
Do not stretch the water hoses intentionally, and
y
make sure that they are not crushed by other
objects.
Water supply pressure must be between 14.5 PSI
y
and 116 PSI (100~800 kPa). If the water supply
pressure is more than 116 PSI, a pressure reducing
valve must be installed.
To provide optimum washing performance the hot
y
water temperature should be set at 120-135°F (48-
57°C) and the cold at 60°F (15°C).
Hot water