Ad6 
‐8~8 
Ad7 
‐8~8 
Ad8 
‐8~8 
rd1 
0~10 
rd2 
0~10 
rd3 
0~10 
rd4 
0~10 
t1 
1~30 
t2 
1~10 
t3 
1~30 
t4 
1~30 
t5 
1~30 
t6 
1~30 
t7 
1~30 
t8 
1~30 
t9 
0~199 
t10 
0~240 
t11 
1~30 
tP9 
‐20~20 
P2 
1~2 
P3 
1~2 
Scy 
1~240 
 
6.4 Error code and solution 
error 
description 
code 
Upper alarm sensor high 
temperature alarm (Temp ≥ MAX of 
setting warning temperature, 
H01 
usually happen when you just 
power on the unit, because at that 
time the cabinet temp has not 
dropped to your setting temp) 
 
10 
10 
10 
60 
10 
evaporator    sensor temperature correction(forbidden) 
upper condenser sensor temperature correction 
lower condenser sensor temperature correction 
set the temperature fluctuates when the upper cabinet 
compressor turn on 
set the temperature fluctuates when the upper cabinet 
compressor turn off 
set the temperature fluctuates when the lower cabinet 
compressor turn on 
set the temperature fluctuates when the lower cabinet 
compressor turn off 
compressor startup delay 
condenser fan stop delay time after compressor stop 
high temperature alarm delay time 
door open alarm delay 
compressor work time if upper sensor error 
compressor turn off time if upper sensor error 
compressor work time if lower sensor error 
compressor turn off time if lower sensor error 
defrosting interval(hours) 
defrosting    time(minutes) 
door heat time of mode 1 
defrosting stop temperature 
condenser fan working mode selection 
evaporator fan working mode selection 
temperature data record interval 
1.
Check the settings of warning temperature are correct for 
you. If not, change the settings using buttons of display panel.         
2. Check the sensor is good and its connection is correct. If sensor 
defective, replace sensor.                                                                     
3.T ry a known good main board. If the issue does not persist, 
replace main board.(rarely)                                                            
4. Refrigerating system failure, please see refrigerating system 
failure part. 