Possible causes of failure / T1
Problem
The compressor does not start
The compressor starts but there is no
pressure
The compressor starts, pressure is
shown on the pressure gauge, but the
tools do not start.
ENGLISH
15
Cause
- No supply voltage
- Insufficient supply voltage
- Outside temperature is too low
- Motor is overheated
- Leak in the non-return valve 15
- The seals are damaged
- Leak in the drain valve 17
- Loose hose connections
- Leak in a quick-lock coupling
- Insufficient pressure set on the
pressure regulator.
15
Solution
- Check the supply voltage, the power plug and the socket-outlet.
- Make sure that the extension cable is not too long. Use an
extension cable with large enough wires.
- Never operate with an outside temperature of below +5°C.
- Allow the motor to cool down. If necessary, remedy the cause of the
overheating.
- Replace the non-return valve
- Check the seals and have any damaged seals replaced by a
service center
- Tighten the screw by hand. Check the seal on the screw and
replace if necessary.
- Check the compressed air hose and tools and replace if
necessary.
- Check the quick-lock coupling and replace if necessary.
- Tighten the pressure regulator further or connect the hose to the
coupling for unregulated tank pressure.