120/240VAC Control Wiring Diagrams
Typical Wiring for one Mat with
SunStat control (120/240VAC)
20-amp circuit.
Ground
Black
120 o 240 VCA
White
Typical Wiring for multiple Mats with
SunStat control (120/240VAC)
20-amp circuit.
Ground
Black
120 or 240VAC
White
Make sure 120 VAC is supplied to 120 VAC mats and 240 VAC is supplied to 240 VAC mats.
Otherwise, dangerous overheating and possible fire hazard can result.
All electrical work must be done by a qualified licensed electrician in accordance with local
building and electrical codes, and the National Electrical Code (NEC), especially Article 424
of the NEC, ANSI/NFPA70 and Section 62 of CEC Part 1.
Line 1
Black
Line 2
White
120/240 VAC
SunStat
Load 1
Black
Line 1
Black
Line 2
Load 2
White
White
120/240 VAC
Control
Load 1
Black
Load 2
White
Sensor Wire
(no polarity)
27 of 96
Heating Mat
(maximum 15 amps)
Sensor Wire
(no polarity)
120 VAC or
240 VAC Heating Mat
(maximum 15 amps)
Two or more 120 VAC or
240 VAC Heating Mats
(maximum 15 amps)