Operating Data; Electric Data - Bticino IME CONTO D4-Pt Manual De Usario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Energy meter on CT/1A - /5A,
indirect connection
5. CONNECTIONS
Wiring diagrams:
F:0,5A gG
L1
L2
L3
F:0,5A gG
L1
L2
L3
Technical data sheet: IDP000191EN_04
3-2E
(1-2)
2
5
8
11
L1
L2
L3
1
3
4
6
7
9
3-2E
(2-3)
2
5
8
11
L1
L3
L2
1
3
4
6
7
9
Updated: 07/01/2020
Codes: CE4TBDTCL1 – CE4TB0PCL1 – CE4TBMTCL1
Model: CONTO D4-Pt
5. CONNECTIONS
Connection on VT:
2
5
8
11
F:0,5A gG
L1
L2
L3
N
(3N-3E)

6. OPERATING DATA

(continues)

6.1 ELECTRIC DATA

Currents:
- Minimum measurement current: 0,05-5(6)A / 0,01-1(1,2)A
Rated voltages:
- Three-phase rated voltage Un:
3x100...3x400V, 3x100/173...3x230/400V
Rated frequency:
- F
: 50Hz; 60Hz
n
- Permitted variation: 49...51Hz; 59...61Hz
Connectable section:
- Copper wires
- Voltage connection terminals (V1, V2, V3, N)
- Current connection terminals(L1, L2, L3)
Without bush
Rigid wire
1 x 1,5 ÷ 16 mm²
Flexible wire
1 x 1,5 ÷ 10 mm²
- Terminal boards in the upper part of the meter (input, impulse
output and bus):
Without bush
Rigid wire
1 x 0,2 ÷ 1,5 mm²
Flexible wire
1 x 0,2 ÷ 1 mm²
Utensili necessari:
- For all measuring terminals: screwdriver with 6mm blade or
Pozidriv No. 2
- For the terminal boards in the upper part of the meter (input,
impulse output and bus): screws with 2.5mm blade
Created: 19/03/2019
2
5
8
F:0,5A gG
L1
L2
L3
(3-3E)
With bush
-
1 x 4 ÷ 10 mm²
With bush
-
1 x 0,2 ÷ 1 mm²