Multi-Volt Element Wiring Configuration: Refer to Figures 5, 6, 7 and 8 for desired voltage
STEP 1
Determine Supply Voltage
Heater must be connected to a GFCI protected branch circuit.
Before installing the heater, it is extremely important you verify the heater is configured for the correct supply voltage.
The Com-Pak Bathroom Heater is configured for 240-Volt operation by default. For 120-Volt installation you must
reconfigure the heater wiring. Installing the heater without configuring for the correct voltage could destroy the
heater and void your warranty.
How to determine the supply voltage:
If replacing an existing heater, check the labels of the old heater and replace using same voltage. For new
construction, heater wires must be configured to the same voltage as the supply wires. If you need assistance, consult
a qualified electrician.
STEP 2
Select Proper Heater Voltage
For 240-Volt configuration:
The Com-Pak Bathroom Heater is configured for
240-Volt operation by default.
240 VOLT POWER SUPPLY
TIMER
THERMOSTAT
JUMPER WITH
3
6
INSULATED Q. D.
1
4
MANUAL RESET
HIGH TEMPERATURE
LIMIT
Figure 5
L1
L2
A
B
Figure 7
CORRECT 240 VOLT CONFIGURATION

Installation Instructions

Part Two
SPARE
TERMINAL
ON
D
A
ELEMENT
TIMER
SHORTING
BAR
C
B
HEATING ELEMENT
HIGH TEMPERATURE
NON-RESETABLE
HIGH TEMPERATURE
LIMIT
Figure 6
MOTOR
C
D
Figure 8
For 120-Volt Configuration:
To configure heater for 120-Volt, disconnect the blue wire
from terminal D and connect it to terminal A. Then
connect the loose red wire to terminal D.
120 VOLT POWER SUPPLY
JUMPER WITH
THERMOSTAT
INSULATED Q. D.
3
6
1
4
MANUAL RESET
NON-RESETABLE
LIMIT
HIGH TEMPERATURE
LIMIT
L1
L2
A
CORRECT 120 VOLT CONFIGURATION
SPARE
TERMINAL
ON
ELEMENT
A
D
SHORTING
BAR
C
B
HEATING ELEMENT
MOTOR
C
B
D
WARNING
Turn the electrical
power off at the
electrical panel
board (circuit
breaker or fuse
box) and lock or
tag the panel board
door to prevent
someone from
turning on power
while you are
working on the
heater. Failure to
do so could result
in serious
electrical shock,
burns, or possible
death.
WARNING
Risk of Electrical
Shock. Connect
grounding lead to
grounding wire
provided. Keep all
foreign objects out
of heater.
WARNING
Risk of Fire.
Heater must be
kept clear of all
obstructions: a
minimum of 3' in
front; 6" on both
sides and above.
Heaters must be
kept clean of lint,
dirt and debris.
P.3