BASIC INSTALLATION INSTRUCTIONS
5.
Attach Filtered Water To Cold Line of Faucet
I.
Attach open end of existing Braided Tubing to Union Fitting on
outlet side (right) of new Filter Head. Hand tighten to avoid damage
to fittings.
6.
Install And Flush Filter Cartridge
J.
Lift handle of the build-in shut off (QC Valve) on the Head.
K.
Hold Head firmly with one hand.
L.
Align cartridge lug with label on filter Head.
M.
Insert filter Cartridge—Push upwards.
N.
Turn it to the right—About 1⁄4 turn—Until rotation stops.
O.
Open cold water valve and check for leaks up to Inlet Elbow Fitting.
P.
Open Water Faucet (not pictured).
Q.
Lower the QC Valve Handle to flush water to the sink.
NOTE: Flush new filter cartridges for at least 3 minutes to remove air
and any loose carbon. At first the water may appear cloudy due to
trapped air in the filter and tubing. If water continues to be cloudy for
more that one week, please contact Everpure Technical Services for
assistance: (800) 942-1153
R.
Remove plastic wrapper and pull Tab from back of Everpure Filter
Timer. The LED and buzzer will cycle 3 times to confirm the start.
It is programmed to flash and sound again in 11 months. Remove
adhesive backing and mount Timer in a convenient location under
the sink.
HEALTH CLAIM PERFORMANCE CLASSIFIED BY UL
This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving
the system, as specified in NSF/ANSI 42 and 53.
Max. Permissible
Influent Challenge
Product Water
Substance
Concentration
Concentration
Standard 42—Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
Particulate,
Class I
at least 10,000
particles 0.5
particles/mL
to <1 µm
Standard 53—Health Effects
Cyst
Minimum 50,000/L
Lead 8.5
0.15 mg/L ± 10%
0.010 mg/L
Lead 6.5
0.15 mg/L ± 10%
0.010 mg/L
Turbidity
11±1 NTU
0.5 NTU
†NTU = Nephelometric Turbidity Units
NOTES:
This installation must comply with all applicable state and local
regulations.
Maximum working pressure 125 psi.
Do no use with water that is microbiologically unsafe or unknown quality
without adequate disinfection before or after the system. Systems certified
for cyst reduction may be used on waters that may contain filterable cysts.
Testing was performed under standard laboratory conditions, actual
performance may vary.
This drinking water system must be maintained according to
manufacturer's instructions, including replacement of filter cartridges.
Suggested retail $129.99.
See page 8 for contact information and manufacturer limited warranty.
Commonwealth of Massachusetts Plumbing Code 248CMR shall be
adhered to. A licensed plumber shall be used for this installation.
continued
Reduction
Minimum
Average
Requirements
Reduction
Reduction
≥ 50%
98%
≥ 85%
99.8%
99.95%
99.99%
99.99%
94.1%
97.2%
98.9%
98.9%
98%
99%
5
5
6
J
N
System Tested and Classified by Underwriters
Laboratories against NSF/ANSI Standards 42 and 53 as
verified and substantiated by test data for the reduction of:
Std. No. 42—Aesthetic effects
Chemical Reduction
ANSI/NSF
Chlorine
STANDARDS
42 and 53
Taste & Odor
Mechanical Filtration
Nominal Particulate Class I
State of California
Department of Public Health
Water Treatment Device
Certificate Number
08 -
Date Issued: February 21, 2008
Trademark/Model Designation
SPA-400 DWS
PBS-400 DWS
Manufacturer: Everpure
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Cysts
Turbidity
Organic Contaminants
None
Rated Service Capacity:
3,000 gals
Conditions of Certification:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for
cyst reduction may be used on disinfected waters that may contain filterable cysts.
I
K
L
Label
M
Lug
Q
O
Std. No. 53—Health effects
Chemical Reduction
Lead
Mechanical Filtration
Cyst
Turbidity
1893
Replacement Elements
SPA-400
PBS-400
Inorganic/Radiological Contaminants
Lead
Rated Service Flow:
2.2 gpm
• 3 •