3.4 Rod balancing
GB
-
Check the choice of the suitable spring, as indicated in the
tables on page 5.
-
Release the motor and place the rod in the vertical opening
position.
-
Insert the spring in the correct position, depending on the
opening direction chosen as indicated in fig. 5.
-
Using the nuts positioned above the spring, compress the
spring until the rod is balanced in a position of 5°-30° com-
pared with the floor (in this position, the rod must remain
still, or tend slightly upwards).
Warning: the compression of the spring [15] must respect
the measurement A indicated in fig. 5.
-
Check also that, in the end positions of opening and clo-
sing, the rod remains still.
Warning: never use the force of the motor to support the
weight of the bar. Always use the balancing spring.
3.5 Adjustment of limit switches QIK4E
-
Regulate the horizontal (closing) and vertical (opening)
positions of the rod by means of the jack screws of the
mechanical stops [14] indicated in fig. 4.
-
Regulate the limit switch sliding blocks [13] for opening
and closing, so that the motor stops 2-3 mm before the
mechanical stop [17].
All right reserved
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take any
responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
QIK4-7 - IP1861
4.
ELECTRICAL CONNECTIONS
The electrical connections and the setting in motion of the barrier
QIK4E are illustrated in the installation manual of the control
panel E1A. Attention: set RF=5 (MAX).
The electrical connections and the setting in motion of the barrier
QIK7EH are illustrated in the installation manual of the control
panel 73RQ.
5. MAINTENANCE SCHEDULE (every 6 months)
Disconnect the 230 V~ power supply and batteries (if used):
-
Clean and oil the levers and check the nuts and screws
are all well tightened.
-
Clean and grease the spring-post as shown in the figure.
-
Check the electrical connections.
-
Check the manual release.
-
Check the balancing of the rod.
-
Check the value of the capacity of the motor condenser.
Connect the 230 V~ power supply and batteries (if used):
-
(Only QIK4E) Check that the limit switches work.
-
Check that the obstacle identification system works.
-
Check that all the command and safety functions work.
WARNING: For the spare parts, refer to the spare parts list.