Programming User Keys; Troubleshooting - Erreka TAGBASE-250 Manual De Instrucciones

Decodificador llaves y tarjetas tag y base receptor enchufable
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Programming user keys

Ensure the memory has sufficient free space to
programme new keys.
Programming using the DIPs
1 Place D1 in "ON" (up).
2 Position the new key to be programmed close to the
reader.
If the decoder receives the code correctly, it stores it in
the memory and gives out a programming conformity
sound (two short beeps).
3 Repeat point "2" with each key to be registered as a user
key.
4 Place D1 in "OFF" (down).
Programming with the master key
The master key must have been programmed first.
1 Position the master key close to the reader.
If the decoder receives the code correctly, it enables
programming of the memory to store new user keys and
gives out a beep lasting approximately 1 second.
3

TROUBLESHOOTING

Before carrying out any maintenance operation,
disconnect the device from the power supply.
Problem
The buzzer beeps (short continuous beeps)
when the power supply is connected
The relay is not activated when the key is
brought near the reader
(DL1 off)
The relay is not activated when the key is
brought near the reader (DL1 on, DL2 lit up
in red)
The relay is activated when the key is brought
near the reader (DL1 on, DL2 lit up in green
when the key approaches the reader) but the
control board does not carry out the order
PLUG-IN RECEIVER BASE AND TAG CARDS AND KEYS DECODER
2 Position the new key to be programmed as the user key
close to the reader.
If the decoder receives the code correctly, it stores it in
the memory and gives out a programming conformity
sound (two short beeps).
3 Repeat point "2" with each key to be programmed as a
user key.
If 10 seconds pass without any programming, memory
programming mode is disabled and functioning mode is
enabled.
Delete master keys
New master keys must be programmed in order to delete
master keys, see "Programming master keys". The new
memorised keys delete the previously memorised master
keys.
Delete user keys
In order to delete the user keys, change the memory for a
new one or delete the memory with the PC IRTAGPROG
console.
Use
To use the device, position the two DIPs (D1 and D2) in OFF.
Cause
The memory card (TAGMEMO) is
not inserted
Absence of power in the decoder
F1 blown
The key is not programmed in the
decoder memory or is not a valid
key
Reader or connections defective, or
connections too long
The key is valid and correctly
p r o g r a m m e d : c o n t r o l b o a r d
connections defective
Solution
Insert the memory card
Establish the power supply voltage
Replace F1 using another of the same
value and investigate the cause of the
failure
Programme a valid key
Check the reader and the connections. If
the reader installation is two-wire,
proceed with three-wire installation.
Check connections