Operation; Maintenance; Cleaning The Filter Of Water Supply Solenoid Valve; Air-Cooled Models - BREMA CB 246 Instrucciones Y Advertencias

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

If the fault still persists after the above checks have been made, switch off the appliance with the switch
fitted during the installation stage, unplug the appliance, turn off the water supply tap and contact one of
the Authorized Service Centers.
To obtain a faster and more efficient reply when you call the Center, state the model of the appliance
precisely, together with its serial number or manufacturing number. This information is given on the
serial N° plate (Fig. 1) affixed to the rear of the appliance and on the cover of this Instruction Manual.
The appliance has a thermostat probe in the ice bin, which stops ice production when the ice
accumulated in the bin reaches the probe connected to the thermostat. When ice is taken from the bin,
the thermostat will automatically reactivate ice-cube production, thus creating a new supply of ice.
9.1 CLEANING THE FILTER OF WATER SUPPLY SOLENOID VALVE (Fig. 8)
!!
At least every two months, clean the filter (14) located on the water inlet solenoid valve, proceeding
as follows:
• switch off the electric power supply by means of the switch (7 Fig. 5), fitted during installation, and
disconnect the plug of the appliance from its socket
• shut off the water supply by turning the tap (8 Fig. 5) fitted during installation
• disconnect the water supply pipe from solenoid valve (11) at the back of the appliance
• using a pair of pliers, remove the filter (14) from its seat without damaging the water feed pipe
connector
• remove any residues by placing the filter under a jet of water; if it is too dirty, replace it with a new filter
identical to the one removed
After having carried out the cleaning operations, refit the filter and hose pipe
When the operations have terminated, turn on both the electricity supply and water supply.
9.2 AIR-COOLED MODELS (Fig. 9)
For air-cooled models, it is very important to keep the finned condenser and its external filter clean.
Have the finned condenser cleaned at least every 2 months by an Authorized Service Center, which can
include the operation in maintenance programs.
The external filter must be cleaned at least once a month, as follows:
• switch off appliance and cut off power supply with the switch (7 in Fig. 5) fitted at the installation
stage
• open plastic grille
• remove filter and keep it at a distance form the appliance
• remove dust from filter by blowing with compressed air
• replace filter in its seat and close plastic grille

9.3 CLEANING AND SANITIZING OPERATIONS

All cleaning operations must be carried out only after the electric power and water supplies
have been disconnected.
The frequency of cleaning and sanitizing operations can vary, depending on:
• temperature and environmental conditions
• temperature and quality of water (hardness, presence of grit, etc.)
• quantity of ice produced, or time of use of ice-cube maker
• periods of non-use of ice-cube maker
TO ENSURE CORRECT CLEANING AND SANITIZING OF THE ICE-CUBE MAKER, PERFORM THE
OPERATIONS DESCRIBED IN THIS MANUAL AT LEAST ONCE A MONTH.