Supply Connection - GE JP380 Guía De Uso Y De Cuidado E Instalación

Asador eléctrico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Supply Connection

All electrical connections are to be protected from the
elements and be in accordance with local codes for
outdoor wiring. This appliance is to be permanently
wired.
Bring supply leads into bottom opening of the internal
wiring box. Make ALL wire connections inside this box.
Install the wiring box cover supplied with this unit and
insure that the cover gasket is in place.
Recommended Minimum
K.W. Rating
on Serial
Plate
0–4.1
4.2–6.9
STEP 2
PREPARING THE COUNTERTOP
Countertop cut-out dimensions
Not less than 1
20
15
16
53.2 .16 cm
" min. cut-out to
Not less than 1
6
3
8
wall (16.2 cm)
4.8 cm
Cut out the opening as shown in the diagram.
Measure carefully when cutting the countertop,
making sure the sides of the opening are parallel
and the front and rear cuts are exactly
perpendicular to the sides.
The front of the opening must clear the front
support rail on the cabinet and the rear of the
opening must clear the rear support of the cabinet.
Chamfer all exposed edges of decorative laminate
to prevent damage from chipping.
Radius corners of cutout and file to insure
smooth edges and prevent corner cracking.
Rough edges, inside corners which have not been
rounded and forced fit can contribute to cracking of
the countertop laminate.
Countertop must be supported within 3"(7.6 cm) of
cutout.
16
INSTALLATION INSTRUCTIONS
Circuit
Wire Size
Protection
AWG
in Amperes
20
12
30
10
Back of Counter
" 3.2 cm
1
4
"
1
16
" (JP380)
28
7
1
8
16
73.3 cm
.16 cm
Front of Counter
"
" min. cut-out to
7
6
3
8
8
wall (16.2 cm)
(continued)
STEP 3
PREPARE FOR DUCTWORK
NOTE: Ductwork MUST be vented outside.
DO NOT vent into a wall, ceiling, crawlspace,
attic or any concealed space.
Determine the best route for ductwork; it can be
routed in a variety of ways depending on the type
of installation.
Typical duct arrangements.
"X10"
3
1
4
(8.2 cm X 25.4 cm)
Transition elbow
Up inside wall to roof or
overhang.
Peninsula or island
Between floor joists.
Optional duct arrangement under concrete slab.
NOTE: PVC sewer pipe type PSM 12454-B
Schedule 40 ASTM D1785.
Wall cap
12"
(30 cm)
min.
6"
(15 cm)
dia. PVC
coupling
6" (15 cm) dia.
PVC sewer pipe
elbow
Inside wall
cabinet
Directly to outside.
"X10"
3
1
4
(8.2 cm X 25.4 cm)
Thru cabinet toe space.
5" to 6"
(12.7 cm to 15 cm)
6" (15 cm)
metal transition
dia. 90°
metal elbow
Concrete
6" (15 cm) dia.
slab
metal duct
16"
6" (15 cm)
(40.6 cm)
dia. PVC
max.
sewer pipe
30' (9.1 m)-0" max
6" (15 cm) dia.
Pack tightly with gravel
PVC sewer pipe
or sand completely
around pipe.
Outside wall
cabinet
Peninsula
Transition
elbow
6" (15 cm)
dia. metal
duct
6"
(15 cm)
dia.
PVC
coupling
6" (15 cm)
dia. PVC
sewer pipe
elbow