Technical Details :
- Power supply
: 230 Vac 50-60Hz 2000W max.
- Flashing light output
: 230 Vac 50-60 Hz
- 2 for Motor output
: 230 Vac 50-60Hz 750 W max.
- Electric lock output
: 12 Vdc 15 W max.
- Services power
supply output
- Safety devices and
controls in LV
- Operating temperature
- Radio receiver
: see model
- Op. transmitters
: Fix - Rolling Code - Plus
-TX max codes in memory : 100 (CODE or PED CODE)
- Board dimensions
153 x 84 x 45 mm.
- Dimensions of container : 160 x 95 x 64 mm.
- DIN Bar Container
List of connections :
CN1 :
1 : Grounding Connection.
2 : Grounding Connection.
3 : Grounding Connection.
CN2 :
1 : 230 Vac line input (Phase).
2 : 230 Vac line input (Neutral)
3 : 230 Vac Flashing light Output (Neutral).
4 : 230 Vac Flashing light Output (Phase).
5 : Opening 230V Motor Output (1).
6 : Common 230V Motor Output (1).
7 : Closing 230V Motor Output (1).
8 : Opening 230V Motor Output (2).
9 : Common 230V Motor Output (2).
10 : Closing 230V Motor Output (2).
CN3:
1 : Power supply to photocells ( 24Vac 6W).
2 : Power supply to photocells (GND).
3 : Electric lock output 12 Vdc 15 W ( +12V ).
4 : Electric lock output 12 Vdc 15 W ( GND ).
5 : Open-close push button control PUL input (NA).
6 : Common GND input.
7 : Pedestrian push button control PUL PED input (NA).
8 : Safety device DS1 input (NC).
9 : Common GND input.
10 : Safety device DS2 input (NC).
CN4:
1 : Aerial earth input.
2 : Aerial hot pole input.
100W Resistive Load max.
50W Inductive Load max.
: 24 Vac 3 W max.
: 24 Vdc
: -10 - 55 °C
: ABS V-0 ( IP40 ).
Programming by SMARTPHONE :
The control unit can only be Programmed via
Smartphone, thanks to the dedicated application
SEAV "BeTech".
The application allows the installer to have a
unique work instrument for all installations performed.
Once the automation has been installed, upon request it will be
possible to also configure any Client Application for normal use
via Smartphone for sending movement commands.
APP Features :
The SEAV "BeTech" application has a Directory where all
installed plant (control units) data is contained. It is also used to
set a Plant Name and Password (Default: 1 2 3 4 ) to
subsequently access the various configurations; the possibility
of restoring a faulty control unit with a new one, reloading all
information contained in the application directory. Furthermore,
by entering an e-mail address, it will be possible to receive a
Back-up of all the plants in case of Smartphone failure.
Possibility to install a new Firmware in the control unit if
necessary, as well as access a Diagnostic for possible
troubleshooting and much more.
Operating Mode :
Step by Step ( default ) :
the first command activates the opening mechanism until the
motor time expires or the opening limit switch is reached, the
second command closes the gate. If a command is sent before
the motor time expires or one of the two limit switches are
reached, the control unit will stop both opening and closing
movements. An additional control re-starts motion in the
opposite direction.
Inverting :
the first command activates the opening mechanism until the
motor time expires. The second command closes the gate. If a
command is sent before the motor time has expired, the control
unit will reverse the motion direction both for opening and
closing.
Inhibition Open Command :
the first command performs activates the opening mechanism
until the motor time expires. The second command closes the
gate. If a command is sent during the opening or pause phase,
it ignores the commands given (e.g. by the loop detector) at
each passage. If a command is sent during closing, the control
unit reverses motion.