ENGLISH
FIG. 1
1
2
6
7
8
5
9
4
3
1.
Test Remote #1 (Red)
2.
F-Connector
3.
Battery Cap
4.
2x AAA Batteries (included)
5.
TEST Button
6.
PASS LEDs
7.
OPEN Fault LED
8.
SHORT Fault LED
9.
Pocket Clip (Back)
NOTE: There are no
user-serviceable parts
inside tester.
VDV512-100 Instructions
GENERAL SPECIFICATIONS
The Klein Tools Coax Explorer
2 verifies proper continuity of F-connector coaxial cables
®
and maps their location. Color-coded push-on remotes allow for up to four cables to be
tested and mapped, displaying cable status via LED indicators (PASS, OPEN, or SHORT)
that also identify the cable/remote location. Remote #1 (red) is included, additional
remotes are available separately.
• Environment: Indoor
• Operating Altitude: 10000 ft. (3000 m) maximum
• Operating Temperature: 32° to 122°F (0° to 50°C)
• Storage Temp: -4° to 140°F (-20° to 60°C)
• Relative Humidity: 10% to 90% non-condensing
• Dimensions (including remote holder): 5.7" x 2.3" x 1.1" (145 x 32 x 29 mm)
• Weight (including batteries): 4.8 oz. (136 g)
Specifications subject to change.
TESTING/MAPPING CABLES
NOTE: Not for use on powered circuits or outlets.
1. Connect test remote 1 to one end of the cable or outlet to be tested. If
necessary, use an F-adapter (not included) to connect the test remote to the cable.
2. Connect the opposite end of the cable or outlet to be tested to the F-connector 2
on the Coax Explorer
2.
®
3. Press and hold the TEST button 5 . If the cable is wired correctly, the top (red)
PASS LED 6 will light. If there is a problem with the cable, one of the FAULT LEDs
(OPEN 7 or SHORT 8 ) will light.
TESTING AN UNINSTALLED CABLE
1. Using an F-adapter (not included), connect a test remote 1 to one end of the
cable to be tested.
2. Connect the opposite end of the cable to be tested to the F-connector 2 on the
Coax Explorer
2.
®
3. Press and hold the TEST button 5 . If the cable is wired correctly, the
corresponding PASS LED 6 will light. If there is a problem with the cable, one of
the FAULT LEDs (OPEN 7 or SHORT 8 ) will light.
BATTERY REPLACEMENT (FIG. 1)
When the TEST button is pressed and no LEDs light, the batteries must be replaced.
1. Unscrew the battery cap 3 .
2. Remove and recycle the two spent AAA batteries 4 .
3. Install two new AAA batteries, with the positive (+) side facing into the tester as shown.
4. Screw battery cap tightly back into place.
Remove the batteries when the tester is not in use for a prolonged period of time. Do not
expose to high temperatures or humidity. After a period of storage in extreme conditions
exceeding the limits mentioned in the GENERAL SPECIFICATIONS section, allow the tester
to return to normal operating conditions before using.
WARRANTY
www.kleintools.com/warranty
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be
properly disposed of in accordance with local regulations. Please see
www.epa.gov or www.erecycle.org for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street, Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
STORAGE