Promaker PRO-CP24 Manual De Usuario página 3

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. Preparation for starting
3. Preparación para el arranque
Fig. 2
L-DAB100 over 10℃, and use SAE10 or L-DAB68 below 10℃ of the
compressor oil.
6. Open the outlet valve, set the knob of pressure switch in position
on (Fig.2), let the compressor run 10 minutes with no load to ensure
lubricating the moving parts before regular service.
4. Operation and adjustment
1. The compressor is controlled by pressure switch when normal
working. It can be stopped automatically as pressure increasing to the
maximum and restart as pressure decreasing to the minimum. The rated
pressure has been adjusted when produced. Don't change it carelessly.
As soon as motor switched
off, the compressed air in
the discharge pipe should be
released through the release
valve under the switch. This
is the necessary condition for
restart, or the motor will be
damaged. The rated pressure
can be adjusted by turning
bolt of the switch (Fig.3).
2. The output pressure of
compressed air can be adjusted by regulating valve. Pull up the knob of
regulation valve and turn it clockwise to increase the pressure (Fig.3).
3. When the compressor in running need to be stopped, only set the
knob of pressure switch in position OFF.
1. Check all bolts and nuts.
Make sure all parts loosened
must be tightened.
2. The place to set the
compressor should be clean,
dry and ventilated.
3. Keep the using voltage
within ±4% of the rated.
4. Keep the oil level in the red
circle of the oil leveler.
5. Recommend SAE30 or
Fig. 3
3
Tabla de contenido
loading

Tabla de contenido