Overhead Rigging; Electrical Installation - JB Systems Light LED illusion Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
DESCRIPTION:
1. Mains cable
2. Ventilation openings: Never cover any ventilation openings as this may result in overheating.
3. Fuse Holder: Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse
of the same type and electrical specifications! (T1A 250V)
4. Optical lenses: Never look directly into the light source
5. Hanging bracket with 2 knobs to fasten the unit and a mounting hole to fix a mounting hook.

OVERHEAD RIGGING

 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

ELECTRICAL INSTALLATION

Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
JB SYSTEMS
®
3/24
OPERATION MANUAL
LED ILLUSION
Tabla de contenido
loading