marklin 76471 Manual Del Usario página 10

Ocultar thumbs Ver también para 76471:
Tabla de contenido
• Programmable addresses by means of CVs 1-2,040 DCC
• Characteristics can be changed by means of CVs
• Power supplied by means of the digital current circuit
Signal Installation
The signal must be programmed before actually installing it.
The following work steps may be done only when there is no
voltage present:
Setting the address and the mode of operation with the DIP switches:
• Setting the mode of operation with DIP Switch 10
Switch 10 off = fx (MM) / mfx
Switch 10 on = DCC
• fx (MM)/DCC Setting the address with DIP switches (See
table starting on Page 18)
Please note: Always do settings with the DIP switches when
there is no voltage present. The signal does not recognize the
current switch settings until the voltage is turned on.
Programming with the CS 2
fx (MM)
The CV programming must be done on the programming track.
Only one signal may be connected to the programming track at
a time.
The following CVs can be changed in fx (MM): CV 40, 45, 48 and 50.
During the programming procedure, the signal light will blink.
During programming with the Central Station, by contrast the
signal is switched. After the end of the programming procedure,
the signal is set at "Go".
An fx dummy locomotive with the address of the signal must be
10
entered before programming with the Mobile Station 2. Activate
the signal once. After that, change the desired CV settings and
switch the signal one more time.
The procedure for programming with the 6021 Control Unit can
be found at www.maerklin.de -> Tools & Downloads ->Tech-
nische Informationen.
Please see the operating instructions for the control devices in
question for programming with other devices.
DCC
CV programming must be done on the programming track. Only
one signal may be connected to the programming track at a
time.
The signal will blink for monitoring purposes during the data
transfer.
Please see the operating instructions for the control devices in
question for programming with other devices.
CV for fx (MM) and DCC
With fx (MM) the address can be set only with the DIP switches.
The values in parentheses are factory default settings.
CV Meaning
1
Address 1 - 255
9
Addresses 256 - 2040
33 Numer of output
addresses
Values
1-255 (1) only DCC
0-7 (0)
only DCC
read only DCC
Tabla de contenido
loading

Este manual también es adecuado para:

76472764917649376494

Tabla de contenido