3. Remove the screw holding the damper assembly,
remove the tape strip and and put the damper
assembly aside. Save this screws, it will be used later to
hold the blower cover plate
Remove both tape strips holding the 7" round duct plate,
4.
and put the duct plate aside.
5. Remove the parts bag taped in the lower left corner of
the hood.
6. Using a 11/32" nut driver, remove the lock nut retaining
the fl ange of the right blower cover plate (shaded part on
illustration beside) to the inner back of hood (see inset).
Remove the right cover plate remaining retaining screws
(6 screws), then set the blower cover along with its screws
and nut aside.
NOTE: Sightly lift up the cover plate before sliding it towards
the left to remove it.
7. Remove the EZ1 brackets from inside the hood by cutting
off the tie wrap. Discard the tie wrap.
8. Remove Electrical Power Cable Knockout from top
(vertical exhaust) or back (horizontal exhaust) of
hood. For knockout removed from back of hood,
install an appropriate strain relief, 1/2" diameter
(not included). For knockout removed from top of hood,
the strain relief will be installed later.
9. Remove 3 screws retaining the recirculation cover plate to the hood. Discard this plate with its screws. Peel off and
discard the membrane (shaded part in illustration below) covering the recirculation grille, ensuring the openings are
totally cleared.
RECIRCULATION
COVER PLATE
.
NON-DUCTED INSTALLATIONS ONLY
SCREWS
PARTS BAG
5
BACK OF HOOD
LOCK NUT
ELECTRICAL
POWER
CABLE
KNOCKOUT
8
TAPE
7" ROUND
DUCT PLATE
TAPE
4
3
6
2
1
7
1 SCREW
DAMPER
ASSEMBLY
S
CREW
REMOVED IN
3
STEP
EZ1