EASYPAD
The Pickproof Alarm
The built-in buzzer will send a continuous beep if the photo-resistant sensor is directly exposed to light.
The buzzer will automatically turn off within 60 seconds if no light is detected or if the admin code is
entered.
Turn on/off the Pickproof Alarm
Access the programming mode, then:
Press "*" and "6" (the indicator will flash yellow), then press "0" and "1". A long beep will be heard whilst the
indicator turns yellow; indicating that the pickproof alarm is being turned off.
Press "*" and "6" (the indicator will flash yellow), then press "0" and "2". A long beep will be heard whilst the
indicator turns yellow, indicating that the pickproof alarm is being turned on.
Press "#" to exit the setting menu.
Turn on/off the Door Bell
Access the programming mode:
Press "*" and "2" (the indicator will flash yellow), then press "0" and "1". A long beep will be heard whilst the
indicator turns yellow, indicating that the doorbell feature is being turned off.
Press "*" and "2" (the indicator will flash yellow), then press "0" and "2". A long beep will be heard whilst the
indicator turns yellow, indicating that the doorbell feature is being turned on.
Press "#" to exit the setting menu.
WARNING: The ZONE 2 relay for doorbell is available if the doorbell feature is turned on. However, door
lock feature is not available.
Press "*" in standby mode, and the relay contacts once: the doorbell is triggered.
Edit the User Code for ZONE 1
Access the programming mode:
Press "*" and "9", the yellow indicator will flash, then press "0" and "2" : a beep will be heard. Then, enter
three numbers from 000 to 999 as initial unit and the relevant code (the code length should be the same as
the admin code).
Press "#" to exit the setting menu.
EASYPAD Wiring
Red: power: +12V/24 AC/DC
Black: power: - 12V/24 AC/DC
Brown: Door status detection – door magnet
Orange: Unlocked button 1 - ZONE 1
Yellow: Unlocked button 2 - ZONE 2
Green: common GND for brown, orange and yellow
Blue: NO 2
Purple: COM 2
output relay 2 (Zone 2) or « door bell » relay
Grey: NC 2
White: NO 1
Pink: COM 1
output relay 1 (Zone 1)
Light-blue: NC 1
Braid: Ground