Cleaning And Maintenance; Technical Specifications - HQ-Power VDL250FL Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

d) Mounting the Device
• Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
• The construction to which the device is attached should be able to support 10 times the weight of the device for
one hour without deformation.
• The installation must always be secured with a secondary attachment e.g. a safety cable.
• Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician
check the device once a year and once before you bring it into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised persons.
• Overhead mounting requires extensive experience: calculating workload limits, determining the installation
material to be used... Have the material and the device itself checked regularly. Do not attempt to install the
device yourself if you lack these qualifications as improper installation may result in injuries.
• Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
• Make sure there is no flammable material within a 0.5m radius of the device.
• Have a qualified electrician carry out the electric connection.
• Connect the device to the mains with the power plug. Don't connect it to a dimming pack.
• The installation has to be approved by an expert before the device is taken into service.
5. Use
Switch the device on and off by means of the power plug. Do not operate the device continuously.

6. Cleaning and Maintenance

1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections, ...
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts, apart from the lamp and the fuse (see "Installation").
8. Contact your dealer for spare parts if necessary.

7. Technical Specifications

Power Supply
Power Consumption
Fuse
Dimensions
Total Weight
Lamp
Max. Ambient Temperature
Max. Housing Temperature
The information in this manual is subject to change without prior notice.
VDL250FL
max. 230VAC / 50Hz
max. 280W
2.5A, 250VAC (5 x 20mm) (order code FF2.5N)
240 x 245 x 120mm
12kg
1 x ELC 24V / 250W halogen (order code LAMP250/24ELCE (incl.),
LAMP250/24ELC (Philips) (not incl.), LAMP250/24ELC5H (Philips
long-life) (not incl.))
45°C
130°C
3
VELLEMAN
Tabla de contenido
loading

Tabla de contenido