Long Term Storage:
1. Drain fuel through the drain plug in the bottom of
the fuel tank.
2. To remove the drain plug, pull the plug grip
downward and remove the seal head from the
drain hole in the tank. (See Figure 4)
Drain Plug
Figure 4
3. Using a small amount of kerosene, rinse and swirl
the kerosene inside of the fuel tank, empty the
tank fully.
4. To replace the drain plug; push the drain head
fully into the drain hole and secure by pushing the
seal cap fully into the head hole.
(See Figure 5)
Figure 5
IMPORTANT: Never store leftover kerosene between
seasons, using old fuel can damage heater.
WARNING
© 2018, Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
Maintenance
Drain Plug Grip
(Pull Down)
Drain Plug
Fuel Tank
Seal Head
Head Flange
Capuchon
Never service
heater while it is
plugged in or hot!
Service:
DO NOT TAMPER WITH THE UNIT. HAVE
A COMPETENT SERVICEMAN MAKE ANY
NECESSARY ADJUSTMENT OR REPAIRS.
Use only original equipment parts. The use of alternate
or third party components can cause unsafe operating
conditions and will void your warranty.
We suggest following a maintenance schedule as follows:
TIP: To order OEM parts call 866-676-1989
FUEL / FUEL TANK:
Flush tank every 200 hours of operation or as needed.
DO NOT flush with water, use fresh K-1 kerosene only.
FAN BLADES:
Blades should be cleaned at least once per heating
season, depending on conditions. Remove all
accumulated dust and dirt with a damp cloth, taking
care not to bend any of the fan blades. Be sure the
blades are dry before re-starting the heater. For fan
assembly removal see Figure 6.
Sirroco Fan
Motor
Figure 6
SilentDrive Forced Air Heater User's Manual
6
Set Screw
Motor Shaft
Fan Blade