Mallory HYFIRE 6EZ Serie Instrucciones De Instalación página 4

Control de arranque electrónico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TO BATTERY POS (+)
TO BATTERY NEG (-)
PART No. 6855
®
STOCK COIL
WIRING
See Figure 2
Remove the factory coil wire and set it aside. Leave all other
wiring on the distributor and coil in place. Connect one of the 2
supplied coil wires from the factory coil tower to the high tension
tower on the end of the HYFIRE
Take the other supplied coil wire and connect it from the new
Mallory coil to the distributor.
Connect the Red wire from the harness to the battery positive
(+) terminal.
Connect the Black wire from the harness to the battery negative
(-) terminal.
Plug the harness connector into the matching connector on the
ignition control.
Note: All of the wires of the HYFIRE
be shortened as long as quality connectors are used or sol-
dered in place.
3
RED (LARGE 14 GA)
BLACK (LARGE 14 GA)
NEW COIL WIRE
®
6EZ Ignition Control.
®
6EZ Ignition Control may
Mallory-Ignition.com
WIRE FUNCTIONS
Power Leads
The two heavy gauge wires (14 gauge) that deliver battery voltage
to the ignition:
Heavy Red Connects directly to the battery positive (+)
terminal or to a positive battery junction. It
could also be connected to the positive side of
the starter solenoid. NOTE: Never connect this
wire to the alternator.
Heavy Black Connects directly to the battery negative (-)
Orange/Black Plugs into the coil connector. These are the
Connector
only wires that make electrical contact with the
ProMaster
®
ROUTING WIRES
Route all wires away from heat sources, sharp edges, and moving
objects. Route the trigger wires separate from the other wires and
spark plug wires. If possible, route them along a ground plane,
such as the block or firewall, which creates an electrical shield.
The magnetic pickup wires should be routed separately and
twisted together to help reduce extraneous interference.
WARNING: The HYFIRE
®
6EZ Ignition Control is a capacitive
discharge ignition. High voltage is present at the coil primary
terminals. Do not touch these terminals or connect test
equipment to them.
NEW COIL
TO DISTRIBUTOR
e
Performance Coil.
Tabla de contenido