Sensica sensiLift ST100 Serie Manual Del Usuario página 40

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is
a ected by absorption and reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
a
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV
broadcast cannot be predicted theoretically with accuracy. To assess the
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey
should be considered. If the measured field strength in the location in which the Sensilift is
used exceeds the applicable RF compliance level above, the Sensilift should be observed
to verify normal operation. If abnormal performance is observed, additional measures
may be necessary, such as re-orienting or relocating the Sensilift.
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
b
IEC 60601-1-2: 2007 Table 6 Requirements
Recommended separation distances between portable and mobile
RF communications equipment and the Sensilift
The Sensilift is intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the Sensilift
can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment
(transmitters) and the Sensilift as recommended below, according to the
maximum output power of the communications equipment.
Rated Maximum
Output Power
of Transmitter W
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended
separation distance d in meters (m) can be estimated using the equation applicable to
the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range
applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is
a ected by absorption and reflection from structures, objects and people.
42
Separation distance according to
frequency of transmitter m
150 kHz to
80 MHz to
80 MHz
d=3.5/3 √
d=3.5/3 √
P=1.17√P
0.12
0.37
1.17
3.70
11.67
800 MHz to
800 MHz
P=1.17√P
P=2.33√P
0.12
0.37
1.17
3.70
11.67
2,5 GHz
d=7/3 √
0.23
0.74
2.33
7.37
23.33

Capítulos

Tabla de contenido
loading

Tabla de contenido