4 - Preselector mode
4.1 - Description of the preselector mode
" .
The CPT4 multifunction electronic counter configured in preselector mode
enables:
- the upcounting/downcounting of electrical pulses,
- the display of current value, taking into account the Gain G, also known
as the weighting factor, or scale factor,
- activation of a contact OUT1 when the value P1 is reached,
- activation of a contact OUT2 when the value P2 is reached,
- manual reset, electrical reset (using input C) or automatic reset by
programming.
- operation with reset to zero or reset to the main preset value.
where:
- P1: intermediate preset.
- P2: main preset.
Note: In the case of a counter with only one preset, P1 is the main preset.
- The output OUT2 is activated, or not, on an intermediate reset, according
to the counter user settings. For units with a single preset, the
corresponding output is OUT1.