Ci-30 KS S-30MP1 IS 15803:2008 AS/NZS 1716:2012 EN 13794:2002
DEZEGA
WARNING!
If the breathing bag is partially filled, breathe out powerfully several times until breathing bag has
been filled.
After donning the self-rescuer:
–
Leave the emergency site walking steadily. Running and fast walking are not recommended.
Hasty breathing consumes more oxygen.
–
Walk slower or stop in case of any breathing difficulties, recover normal breathing rhythm
and then continue walking.
WARNING!
Do not remove mouthpiece or nose clip, do not try to talk through it, and do not inhale the surrounding air
before arriving at a known fresh air location.
Gradual heating of self-rescuer casing up to:
–
60 °C on the wearer's side of heat shield;
–
100 °C on apparatus surface;
is expected and is a sign of normal operation. Normal cotton clothing should provide an acceptable
level of comfort from the increases in temperature of the case.
WARNING!
Using of heat shield is a must for your safety to avoid overheat.
Step 6:
•
Adjust the length of the neck strap by
pulling on the pull tab with right hand
and lifting the unit with your left hand to a
comfortable position.
•
Weight of the self-rescuer should not pull
the mouthpiece out of your mouth.
•
Circle around your body the left (long) end
of the chest strap, fasten it, and adjust
the length by pulling on the pull tab with
the right hand.
•
Put on protective goggles.
•
Calmly follow the escape route to a place
of safety.
The total time of donning procedure
should take no more than
15 seconds.
13