SAFETY INFORMATION
•
Use this appliance only as described in the manual. Any other use is NOT recommended by the
manufacturer and may cause fire, electric shock or injury to persons.
CAUTION
• If possible, ALWAYS unplug this appliance when not in use.
•
DO NOT operate any heater with a damaged cord or plug or after the heater malfunctions.
DO NOT operate any heater if it has been dropped or damaged in any manner. Disconnect
power at service panel and have heater inspected by a reputable electrician before reusing.
•
Any repairs to this fireplace should be carried out by a qualified service person.
•
Under no circumstances should this fireplace be modified. Parts having to be removed for
servicing must be replaced prior to operating this fireplace again.
•
DO NOT use outdoors.
•
This heater is not intended for use in bathrooms, laundry areas and similar indoor locations.
NEVER place heater where it may fall into a bathtub or other water container.
•
To disconnect this appliance, turn controls to the off position, then remove plug from outlet.
ONLY connect to properly grounded outlets.
•
This appliance, when installed, must be electrically grounded in accordance with local codes,
with the current CSAC22.1 Canadian Electrical Code or follow the National Electrical Code,
ANSI/NFPAN0.70.
•
To prevent a possible fire, DO NOT block air intakes or exhaust in any manner. DO NOT use
on soft surfaces, like a bed, where opening may become blocked.
•
The heaters MUST NOT be located immediately below a socket-outlet.
•
ALWAYS plug heaters directly into a wall outlet/receptacle. NEVER use with an extension
cord or re-loadable power tap (outlet/power strip).
•
There is a thermostat limiter inside the item. If the inner temperature overheats or abnormal
heating occurs, the thermostat protective device will cut off power supply to prevent damage
or risk of fire.
•
DO NOT slide insert on top of wood to avoid scratching wood surface.
•
DO NOT place any objects on top of insert and top air intake vents as this will cause unit to
overheat and can cause a fire.
Electrical Connection
Voltage
120 VAC, 60 Hz
• A 15-amp, 120-volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the
fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the
circuit breaker to trip or the fuse to blow when the heater is in operation. The unit comes
standard with 6-ft. three-wire cord, exiting from the rear of the fireplace. DO NOT exceed the
current rating of the current tap. ALWAYS plug heaters directly into a wall outlet/receptacle.
NEVER use with an extension cord or relocatable power tap (outlet/power strip).
SPECIFICATIONS
Amps
12.5 Amps
4
Watts (max.)
1500 Watts