Input specification, pin assignment and adjustable operating modes (DC versions).
A control input (screw terminal 5) allows adjusting the operating mode.
Screw terminal
Nr. 1
Designation
Model
6.130.012.8x0
07 kHz
6.130.012.8x2
12 kHz
6.131.012.8x0
07 kHz
6.131.012.8x1
12 kHz
6.133.012.8x0
03 kHz
6.133.012.8x1
06 kHz
Table 2
Screw terminals 1 and 2:
Function and max. frequences(Pulse/Pause 1:1)
see Table 2
NPN :
active for negative edge
Input resistance:
approximately 1 MOhm
Low level:
0 ... 0,7 V DC
High level:
3 ... 30 V DC
Screw terminal 3:
Reset input, active for negative edge
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
0 ... 0,7 V DC
High level:
3 ... 30 V DC
Min. pulse duration:
50 ms
Input resistance:
approximately 2,2 MOhm
Screw terminal 5:
Operating mode switch (Mode)
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
0 ... 0,7 V DC
High level:
3 ... 5 V DC
Input resistance:
approximately 2,2 MOhm
Function:
see Table 2
9
Nr. 2
INP A
INP B
NPN
30 Hz
NPN
PNP
NPN
NPN
07 kHz
NPN
PNP
12 kHz
PNP
NPN
03 kHz
NPN
PNP
06 kHz
PNP
Nr. 3
Nr. 4
Nr. 5
Reset Reset
Control inputs for operating
Enable
not active
=
adding
not active
=
Cnt.Dr Mode
not active
=
Quad Mode
PNP :
Input resistance:
Low level:
High level:
Screw terminal 4:
Electrical locking of the reset key
Contact input / Open Collector NPN
(switching at 0 V DC)
Low level:
High level:
Input resistance:
Input not active:
Input in contact
with GND:
Screw terminal 6:
GND connection common for all inputs
Screw terminal 7:
(–) external power supply for the LCD backlight option
Screw terminal 8:
(+) external power supply for the LCD backlight
option(24 V DC ±20%, 50 mA)
Nr. 6 Nr. 7
GND
mode (Mode)
contact with
GND =
subtracting
contact with
GND =
Up.Dn Mode
contact with
GND =
Quad2 Mode
active for positive edge
approximately. 100 kOhm
0 .. 0,7 V DC
4 .. 30 V DC
0 ... 0,7 V DC
3 ... 5 V DC
approximately. 2,2 MOhm
Reset key locked
Reset key unlocked
Nr. 8
BL
BL
–
+