Important - S&P EBB-175 DESIGN Manual De Instrucciones

Ocultar thumbs Ver también para EBB-175 DESIGN:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
ENGLISH
EBB Centrifugal Extractor Fans
The EBB range has been manufactured to
the rigorous standards of production and
quality as laid down by the international
Quality Standards ISO 9001. All the
components have been checked and all
the final products have been tested at the
end of the manufacturing process.
Please read this instructions booklet
carefully before installing or starting up
the
product.
information on personal and user safety
measures to be followed while installing,
using and carrying out maintenance work
on the equipment.
Important information
- Check that the apparatus is in perfect
condition while unpacking. Any fault or
damage caused in origin is covered by
the S&P guarantee. Please make sure
that the apparatus coincides with the
product you have ordered and that the
details on the instructions plate fulfil
your necessities.
- Installation must only be carried out by
qualified persons.
- Make
sure
complies with each country's current
mechanical and electrical norms.
- If a ventilator is going to be installed to
extract air from premises where a
boiler or other combustion apparatus
are installed, make sure that the
building has sufficient air intakes to
assure adequate combustion.
- The extractor outlet must not be
connected to a duct used to exhaust
smoke or fumes from any appliance
that uses gas or any other type of fuel.
- This appliance is not intended for use
by young children or infirm persons
unless they have been adequately
supervised by a responsible person to
ensure that they can use the appliance
It
contains

important

that
the
installation
safely. Young children should be
supervised to ensure that they do not
play with the appliance
Installation
IMPORTANT:
Before
wiring the EBB, ensure that the main
supply is disconnected.
Suitable
for
both
installation, the EBB fans may be
adapted to an individual duct or to a
communal ventilation system (Fig. 1).
The discharge port, situated at the side
on the back of the extractor housing,
enables it to be installed anywhere on the
wall or ceiling, even in inaccessible
corners (Fig.2).
NOTE: Pullcord models M and HM
should be mounted as shown in Fig.2.1 If
NOT mounted as Fig.2.1, a support (not
supplied) must guide the pullcord so that
it does not rub the fan body. The pullcord
(if used) MUST be easy to operate.
Making use of the template enclosed,
make a 100 mm diameter round hole in the
wall or ceiling.
NOTE: A 115mm dia. hole is required if a
wall sleeve is utilized.
Drill the holes for the screws and insert
the respective plugs in them. Take the
extractor fan and withdraw the grille by
pressing on the shoulders at the bottom
(Fig.3).
If the installation is made to an individual
ducting, use standard ducting of 100 mm
diameter. Smaller diameter must not be
used. If it is necessary to bend the duct at
the discharge of the fan, make the radius
as large as possible.
Before fixing the fan support, ensure that
there are no obstructions to the airflow, that
installing
and
ceiling
and
wall
loading

Este manual también es adecuado para:

Ebb-250 designEbb-175Ebb-250