GYS FLASH 10.36/48 PL Traducción De Las Instrucciones Originales página 12

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Translation of the original instructions
3
Step
: Test
Sulfated battery test
4
Step
: Desulfation (
Battery desulfation algorithm.
• Lithium charging curve :
The GYSflash 10.36/48 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your
lithium battery.
1
Step
: Analysis
Analyses the state of the battery (charge level, polarity inversion,
wrong battery...)
2
Step
: Recovery (
Recovery algorithm following a deep discharge.
3
Step
: Charging (
Fast charging at maximum current up to 90%.
of the charge level.
4
Step
: Absorption
Constant voltage charging to bring the charge level to 98%.
/
LiFePO4
51.8 V
Li-ion
52.7 V
• Estimated charge time :
Charging current
Battery capacity
Charge timing 0% >90%
12
GYSFLASH 10.36/48 PL
- 47.4 V /
- 62 V)
- 2 A /
- 2 A)
- 10 A /
- 8 A)
/
55.2 V
41.4 V
56.7 V
40.5 V
Lead-acid
8 A
20 Ah
50 Ah
100 Ah
160 Ah
2 h
6 h
12 h
20 h
7
Step
: Floating mode (
Maintaining the battery charge level at its maximum.
5
Step
: Test
Charge hold test.
6
Step
: Complement
Reduce current charge to reach 100% charge level.
7
Step
: Equalization / Balancing
Balancing the battery cells
LiFePO4
Li-ion
8
Step
: Floating mode
Maintain the battery charge level at its maximum with main-
tenance charge every 10 days.
LiFePO4
51.75 V
Li-ion
52.7 V
10 A
60 Ah
150 Ah
230 Ah
8 Ah
6 h
15 h
23 h
1 h
- 40.8 V /
/
/
54 V
57.6 V
43.2 V
54 V
58.1 V
41.5 V
/
/
55.2 V
41.4 V
56.7 V
40.5 V
Lithium
8 A
30 Ah
120 Ah
160 Ah
30 Ah
3.5 h
15 h
20 h
EN
- 54.4 V)
10 A
140 Ah
230 Ah
3 h
14 h
23 h
Tabla de contenido