2. C

ONTROLS

2.1 I
NTEGRATED
B
S
OOTING
EQUENCE
The unit booting sequence is similar to a personal computer booting
sequence. Each time the unit is plugged after being unplugged, or after a
power failure, the unit will perform a 30-second booting sequence before
starting to operate.
During the booting sequence, the integrated control LED (2 in illustration
below) will light AMBER for 10 seconds. After that, the LED will light RED
for the rest of the booting sequence. During this RED light phase, the unit is
checking and resetting the motorized damper position. Once the motorized
damper position completely set, the RED light turns off and the booting
sequence is done.
NOTE: No command will be taken until the unit is fully booted.
All units are equipped with an integrated control, located under the unit, on the
recessed side of electrical compartment. Plug the unit.
Use the push button (1) to control the unit. The LED (2) will then show on
which mode the unit is in.
VD0207
Refer to table below to see how to operate the unit using its integrated control.
P
RESS ON PUSH BUTTON
If a problem occurs during the unit operation, its integrated control LED (2)
will blink. The color of the blinking light depends on the type of error detected.
Refer to Section 4 Troubleshooting on page 9 and 10 for further details.
NOTE: WHEN USING MAIN CONTROL, THE INTEGRATED CONTROL
MUST BE TURNED OFF.
C
ONTROL
O
NCE
T
WICE
T
HREE TIMES
2
1
B
OTTOM OF THE UNIT
LED C
OLOR
A
MBER
G
REEN
N
O LIGHT
4
R
ESULTS
U
L
NIT IS ON
OW SPEED
U
H
NIT IS ON
IGH SPEED
U
OFF
NIT IS