aDDITIonal FeaTURes:
ReseRvoIR FUll lIGhT
• Illuminates when the reservoir is ready to be
emptied, or when the reservoir is removed and
not seated in the proper position .
aUTo shUT oFF
• The dehumidifier shuts off after 30seconds
when the reservoir is full, or when the reservoir
is removed or not seated in the proper position .
When the desired humidity level is reached, the
unit will also shut off automatically . On some
models, the fan motor will continue operating .
aUTo DeFRosT
• When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will contin-
ue to run until the frost disappears .
aUTo pRoTeCT
• Once the unit is turned off, it can not restart op-
ertation for the first 3 minutes . This is to protect
the unit . Operation will automatically resume
after 3 minutes .
CheCK FIlTeR
• The system keeps count when the fan motor
operates and illuminates the clean filter light
after 250 hours of operation (every 10 days if in
continuous use) . The indicator light flashes one
time each second .
• After cleaning the air filter, press the filter button
on the control panel and the indicator turns off .
$$$ save & ConseRve eneRGy
• Use the unit in the recommended room size .
• Locate the unit where furniture cannot obstruct the air flow .
• Keep the filters clean .
• Keep doors and windows closed .
aUTo ResTaRT
• If the power goes out, the unit will restart with
the previous function settings automatically
when power returns .
TIMeR FUnCTIon
• The timer indicator lights are for two separate
functions, one to automatically turn the unit on
and another to automatically shut it off . Both
programs can be set at the same time .
setting the unit to automatically turn off:
• Push the timer button once (if dehumidifier is
running) or twice (if dehumidifier is not running)
until the 'OFF' indicator illuminates
• Use the + and – pad to select the number of
hours before the unit automatically turns off .
• The time will be programmed after 5 seconds of
inactivity and the display will return to show the
humidity level .
setting the unit to automatically turn on:
• Push the timer button once (if dehumidifier is not
running) or twice (if dehumidifier is running) until
the 'ON' indicator illuminates .
• Use the + and – pad to select the number of
hours before the unit automatically turns off .
• The time will be programmed after 5 seconds of
inactivity and the display will return to show the
humidity level .
noTe: Both 'ON' and 'OFF' indicators can be illu-
minated—the unit will automatically turn itself
on and off according to the programmed times .
8