Warnings For The Installer - V2 ARGO 160 Manual Del Usario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS
ATTENTION! To ensure the safety of people, it is
important that you read all the following instructions.
Incorrect installation or incorrect use of the product
could cause serious harm to people.
Carefully read the instructions before beginning to install the
product.
Do not leave packing materials (plastic, polystyrene, etc.)
within reach of children as such materials are potential
sources of danger.
Store these instructions for future reference.
This product was designed and built strictly for the use
indicated in this documentation. Any other use, not expressly
indicated here, could compromise the good
condition/operation of the product and/or be a source of
danger.
V2 SPA declines all liability caused by improper use
or use other than that for which the automated system was
intended.
Do not install the equipment in an explosive atmosphere:
the presence of inflammable gas or fumes is a serious danger
to safety.
The mechanical parts must conform to the provisions of
Standards EN 12604 and EN 12605.
For non-EU countries, to obtain an adequate level of safety,
the Standards mentioned above must be observed, in
addition to national legal regulations.
V2 SPA is not responsible for failure to observe Good
Technique in the construction of the closing elements to be
motorised, or for any deformation that may occur during use.
The installation must conform to Standards EN 12453 and
EN 12445. For non-EU countries, to obtain an adequate level
of safety, the Standards mentioned above must be observed,
in addition to national legal regulations.
Before attempting any job on the system, cut out electrical
power.
The mains power supply of the automated system must be
fitted with an all-pole switch with contact opening distance
of 3mm or greater. Use of a 6A thermal breaker with all-pole
circuit break is recommended.
Make sure that a differential switch with threshold of 0.03 A
is fitted upstream of the system.
Make sure that the earthing system is perfectly constructed,
and connect metal parts of the means of the closure to it.
The safety devices (EN 12978 standard) protect any danger
areas against mechanical movement Risks, such as crushing,
dragging, and shearing.
Use of at least one indicator-light is recommended for every
system, as well as a warning sign adequately secured to the
frame structure, in addition to the safety devices.
V2 SPA declines all liability as concerns safety and
efficient operation of the automated system, if system
components not produced by V2 SPA are used.
For maintenance, strictly use original parts by V2 SPA.
Do not in any way modify the components of the automated
system.
The installer shall supply all information concerning manual
operation of the system in case of an emergency, and shall
hand over to the user the warnings handbook supplied with
the product.
Do not allow children or adults to stay near the product
while it is operating.
Keep radiocontrols or other pulse generators away from
children, to prevent the automated system from being
activated involuntarily.
The user must not attempt any kind of repair or direct action
whatever and contact qualified personnel only.
Transit is permitted only when the automated system is idle.
Maintenance: check at least every 6 months the efficiency
of the system, particularly the efficiency of the safety devices
(including, where foreseen, the operator thrust force) and of
the release devices.
Anything not expressly specified in these instructions
is not permitted.
EC DECLARATION OF INCORPORATION FOR
PARTLY COMPLETED MACHINERY
(DIRECTIVE 2006/42/EC, ANNEX II-B)
The manufacturer V2 S.p.A., headquarters in
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s):
ARGO 160, ARGO 160 FR, ARGO 170, ARGO 170 FR
ARGO 300, ARGO 300 FR
Description: electromechanical actuator for
SPRING BALANCED ROLLING SHUTTER
• is intended to be installed on rolling shutter, to create a
machine according to the provisions of the Directive
2006/42/EC.
The machinery must not be put into service until the final
machinery into which it has to be incorporated has been
declared in conformity with the provisions of the Directive
2006/42/EC (annex II-A).
• is compliant with the applicable essential safety requirements
of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2006/95/EC
Electromagnetic Compatibility Directive 2004/108/EC
Directive ROHS2 2011/65/CE
The relevant technical documentation is available at the national
authorities' request after justifiable request to:
V2 S.p.A.
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
The person empowered to draw up the declaration and to
provide the technical documentation:
Cosimo De Falco
Legal representative of V2 S.p.A.
Racconigi, 10/01/2014
6
Tabla de contenido
loading

Este manual también es adecuado para:

Argo 160-frArgo 170Argo 170-frArgo 300Argo 300-fr

Tabla de contenido