Dimplex LC Serie Guia De Inicio Rapido

Dimplex LC Serie Guia De Inicio Rapido

Zócalo convector lineal

Enlaces rápidos

IMPORTANT INSTRUCTIONS
When using electrical appliances, basic precautions should always
be followed to reduce the risk of fire, electric shock and injury to
person, including the following:
1. Read all instructions before using this Linear Convector
Baseboard.
2. Heater and controls should be installed by a qualified contractor.
Wiring procedures and connections should be in accordance with
the National Electric Code (CEC & NEC) and local codes.
3. A Linear Convector Baseboard has hot and arcing or sparking
parts inside. Do not use it in areas where gasoline, paint or
flammable liquids are used or stored.
4. This Linear Convector Baseboard is hot when in use. To avoid
burns, do not let bare skin touch hot surfaces. Keep combustible
materials such as: furniture, pillows, bedding, papers, clothes and
curtains away from Linear Convector Baseboard.
5. To prevent a possible fire, do not block air intakes or exhaust
in any manner. Do not use on soft surfaces like a bed where
openings may become blocked.
6. Do not insert or allow foreign objects to enter any ventilation or
exhaust opening as this may cause an electric shock or fire, or
damage the Linear Convector Baseboard.
7. Do not install these Linear Convector Baseboards against
combustible, low density cellulose fibre surfaces or vinyl wallpaper.
8. Do not locate these Linear Convector Baseboards below any
electrical convenience receptacles.
9. Check Linear Convector Baseboard nameplate ratings to be sure
Linear Convector Baseboard voltage is the same as the service
supply. (The nameplate is located below the right side of the
heating element.)
10. HIGH TEMPERATURES: Keep electrical cords, furniture,
draperies or any other blocking material away from the Linear
Convector Baseboard.
SAVE THESE INSTRUCTIONS
Installation Instructions
PLACEMENT OF THE LINEAR CONVECTOR
BASEBOARD
Linear Convector Baseboards are high performance heaters designed
to operate at higher outlet temperatures than conventional baseboard
heaters. They are to be mounted with the included optimizer kit onto
drywall, plaster, wood or concrete walls.
!
NOTE: If the unit is being installed on a newly constructed wall,
ensure that all products that have been applied are fully cured
according to manufacturer's instructions, before operating the unit.
!
NOTE: Failure to install optimizer kit will increase the wall
temperature and may discolor or deform some materials (e.g. vinyl
or plastic).
RECOMMENDATIONS FOR LOCATING DRAPES AND
FURNITURE NEAR HEATER (FIGURE 1)
!
NOTE: Any objects or materials that are located within the distances
outlined below should not discolor, nor distort dimensionally (stretch
or shrink) upon extended exposure ( up to 1000 hrs.) to temperatures
of 200º F (93º C).
For most satisfactory operation of the heaters and minimum effect
on drapes, furniture and objects in close proximity, the following
recommendations should be observed:
1. Full Length Drapes: Hang drapes so there is at least 1.5" (3.8 cm)
between the top of the drapes and the ceiling, at least 1.5" (3.8cm)
between the bottom of the drapes and the finished floor covering
(such as carpet, if used) AND at least 3" (7.6 cm) between the front
vertical surface of the heater and the nearest fold of the drapes
(opened drape). (Figure 1A)
Linear Convector Baseboard
LC Series
Figure 1
A
B
Min.
1.5" (3.8 cm)
Min.
1.5" (3.8 cm)
Min.
6" (15.3 cm)
Min.
1.5" (3.8cm)
Min.
3" (7.6 cm)
2. Shorter Length Drapes: Hang drapes so there is at least 1.5"
(3.8 cm) between the top of the drapes and the ceiling, and at least
6" (15.3 cm), preferably more, between the bottom of the drapes
and the top horizontal surface of the heater. (Figure 1B)
3. Furniture: Place furniture no closer than 3" (7.62 cm) from the front
of the Linear Convector Baseboard. (Figure 1D)
4. Overhanging Solid Objects (Except Plastic): Position Linear
Convector Baseboard so there is at least 14" (35.6 cm) between
the top of the heater and any solid object that obstructs or redirects
the vertical air flow out of the top of the unit. (Figure 1C)
5. Overhanging Plastic Objects: All Plastic items that cannot
withstand extended exposure to temperatures 60º C or higher
should be kept a minimum of 20" (50.8 cm) above the unit.
(Figure 1C)
!
NOTE: Ensure that when 2 Linear Convector Baseboards
are installed near the same corner they are both a minimum of
6" (15.3 cm) from the corner.
FACTORY WIRING OF THE LINEAR CONVECTOR
BASEBOARD
All Linear Convector Baseboards have provisions for connection
to either end of the Linear Convector Baseboard. The lead wires
at either end are factory spliced with wire nuts as a closed circuit.
The circuit may be opened at either wire nut connection to make
connections to the power supply and/or to the desired controls. (See
Wiring Diagrams)
CONTROLS (not included)
A thermostat control (wall mounted or built-in) is required to operate
this unit. Typical Dimplex controls:
• Built-in thermostat kits: DTK-SP, DTK-DP, DTKT-SP or DTKT-DP
• External line voltage thermostats: TS521W, TD522W, HTC521W,
HTC525W, HTC621W or HTC625W
• Built-in low voltage relay: BLLVCxx or BLLVD
INSTALLATION
WARNING: Disconnect power supply before installation to
prevent electric shock.
1. Unpack and place Linear Convector Baseboard on floor face up,
use packaging to protect floor if required. Remove front covers.
!
NOTE: Remove the center cover, by releasing the top first.
!
NOTE: Heater fins can be easily bent. For optimal performance
ensure that they remain vertical.
2. Orient unit in desired location and mark pilot holes - top and bottom
at both ends and at least one set in middle.
3. Wire unit as per diagrams on page 6 and National and Local
Electrical Codes.
CAUTION: Connect heaters to a branch circuit used only for
permanently installed heater and protected by over current devices
rated or set at no more than 30 amperes. The total connected load
should not be more than 80% of the rating of the over current
devices. It may cause a fire hazard if not installed and maintained
in accordance with these instructions.
C
D
Min.
3" (7.6 cm)
Min.
See Item 4 & 5
for Dimension
Min.
3" (7.6 cm)
7210940100R18
loading

Resumen de contenidos para Dimplex LC Serie

  • Página 1 A thermostat control (wall mounted or built-in) is required to operate to operate at higher outlet temperatures than conventional baseboard this unit. Typical Dimplex controls: heaters. They are to be mounted with the included optimizer kit onto • Built-in thermostat kits: DTK-SP, DTK-DP, DTKT-SP or DTKT-DP drywall, plaster, wood or concrete walls.
  • Página 2 Any claims under this Warranty must be submitted in writing to certain the power has been turned off at the circuit breaker panel, the Service Manager, Dimplex North America Ltd., 1367 Industrial Rd., to prevent electric shock. Cambridge, Ontario N3H 4W3, Canada.
  • Página 3 NOTE: Si 2 plinthe-convecteurs linéaires sont installés près d’un Les appareils de chauffage Dimplex ont été conçus et testés pour même angle mural, s’assurer qu’elles sont placées à au moins 6 po un fonctionnement sans problème. Tous les appareils de chauffage (15,3 cm) de l’angle.
  • Página 4 à toute demande liée à la garantie, le fabricant réparera ou remplacera sans directeur du service à la clientèle à : Dimplex North America Limited, 1367 frais, en usine ou chez le client, à sa discrétion, toute pièce jugée défectueuse.
  • Página 5 Todo reclamo bajo esta garantía se debe presentar por escrito de Zócalo convector lineal. Cuando las unidades se instalan extremo al Gerente de Servicio, Dimplex North America Ltd., 1367 Industrial Rd., con extremo, una los zócalo convectores lineales para asegurar la Cambridge, Ontario N3H 4W3, Canadá.
  • Página 6: Wiring Instructions/ Instructions De Raccordement / Instrucciones Para El Cableado

    Conformément à notre politique visant à améliorer sans cesse nos produits, nous nous réservons le droit d’effectuer des modifications sans préavis. De acuerdo con nuestra política de continua mejora del producto, nos reservamos el derecho a realizar cambios sin previo aviso. © 2018 Dimplex North America Limited...