STEP 9 REPLACE FRESH FOOD
DOORS
A. Reinstall center hinge first and torque the
screws to 65 in-lbs. With the LH door at 90º to the
front ofthe case, lower the refrigerator door onto the
center hinge. Ensure that the door and hinge align
correctly.
B. Rotate door closed and make sure moveable center
sealing portion of the door aligns with the striker. If
the door will not self-close after reinstalling, remove
door, turn door upside down, check alignment mark
and arrow; (there is an alignment mark on the door
closure mechanism It corresponds to an alignment
mark on the bottom end cap. Rotate door closure
mechanism to align mark and arrow, reinstall door).
Underside of
Fresh Food Door
If door cannot be installed at 90° follow steps below:
1. If space or model limits opening door to less than 180°, then:
a) Remove door, carefully turn door upside down.
b) Check alignment of door closure mechanism shaft on
underside of door. The flats on the shaft should correspond
to alignment tab on plastic ring or mark on bottom end cap.
c) If shaft is not aligned to tab/mark, using 5/32" Allen
wrench, rotate door closure mechanism shaft
counterclockwise for right door and clockwise for left door.
Then align flat with tab/mark.
d) Install the door at 90°.
Securely tape the door shut with masking tape or
have a second person support the door. Reinstall
the top hinge and torque the screws to 65 in-lbs.
C. Be sure to reinstall the ground wire and strain relief
to the top hinge.
D. Reinstall the hinge cover. Note: Ensure wires are
not pinched or under screw bosses before tightening
screws.
E. Follow the same procedure on the opposite door.
Installation Instructions
Align marks
align marks

STEP 10 INSTALL WATER LINE

Recommended copper water supply kits are WX8X2,
WX8X3 or WX8X4, depending on the amount of tubing
you need. Approved plastic water supply lines are
SmartConnect ™ Refrigerator Tubing (WX08X10006,
WX08X10015 and WX08X10025).
When connecting your refrigerator to a Reverse
Osmosis Water System, the only approved installation
is with a GE Appliances RVKit. For other reverse
osmosis water systems, follow the manufacturer's
recommendations.
If the water supply to the refrigerator is from a Reverse
Osmosis Water Filtration System (RO)AND the
refrigerator also has a water filter, use the refrigerator's
filter bypass plug. Using the refrigerator's water
filtration cartridge in conjunction with an RO water filter
can result in hollow ice cubes. Some models do not
come equipped with the filter bypass plug. To obtain a
free bypass plug, call 800-GECARES. In Canada call
800.561.3344.
This water line installation is not warranted by the
refrigerator or ice maker manufacturer. Follow these
instructions carefully to minimize the risk of expensive
water damage.
Water hammer (water banging in the pipes) in house
plumbing can cause damage to refrigerator parts and
lead to water leakage or flooding. Call a qualified
plumber to correct water hammer before installing the
water supply line to the refrigerator.
To prevent burns and product damage, do not hook up
the water line to the hot water line.
Do not install the ice maker tubing in areas where
temperatures fall below freezing.
When using any electrical device (such as a power
drill) during installation, be sure the device is double
insulated or grounded in a manner to prevent the
hazard of electric shock, or is battery powered.
All installations must be in accordance with local
plumbing code requirements.
• Copper or SmartConnect ™ Refrigerator Tubing kit,
1/4" outer diameter to connect the refrigerator to the
water supply. If using copper, be sure both ends of
the tubing are cut square.
To determine how much tubing you need:
measure the distance from the water valve on the back
of the refrigerator to the water supply pipe. Be sure
there is sufficient extra tubing to allow the refrigerator
to move out from the wall after installation.
SmartConnect ™ Refrigerator Tubing Kits are available
in the following lengths:
6' (1.8 m)
– WX08X10006
15' (4.6 m)
– WX08X10015
25' (7.6 m)
– WX08X10025