MOUNTING AND INSTALLATION
4.1.3
Considering the product location
4.1.3.1
Surrounding conditions
► Ensure that the room in which the appliance is installed
is not heated to the maximum recommended room
temperature.
Recommended room temperature: 25°C.
► Do not install the product above another product that
could damage it (for example, above a cooker that might
emit steam or grease) or in a room, which has a lot of
dust in the atmosphere which is corrosive.
► Make sure that the room where you want to fi t the
product is suffi ciently protected against frost.
4.1.3.2
Properties of the mounting surface
► Before choosing a site for the product, carefully read
the safety warnings and instructions in the operating
instructions and installation instructions.
► Ensure that the wall to which the product will be mounted
on is structurally safe in order to support the weight of the
product.
4.2

Mounting the product

4.2.1

Removing the casing

1
1
Front casing
► Remove the front casing (1).
44
4.2.2
Wall-mounting of the product
Danger!
a
Danger to life if the load-bearing
capacity of the fixing elements
used is insufficient!
If the fixing elements do not have
sufficient load-bearing capacity, the
product can come loose and fall
down.
When fitting the product, ensure
that the fixing elements have a
sufficient load-bearing capacity.
► Determine the assembly location.
► Drill the holes to receive the fastenings (see chapter 4.1).
► Fix the hanging bracket on the wall.
1
Hanging bracket
► Lifting the product into position, lean the top of the product
slightly to the wall and position just above the hanging
bracket.
► Lower the product slowly and engage onto the hanging
bracket.
► This product is for internal installation only.
4.3

Hydraulic installation

Caution!
b
Risk of damage caused by
contaminated lines!
Foreign bodies such as welding
remnants, sealing residue or dirt in
the supply lines can cause damage
to the product.
Flush the supply lines thoroughly
before installation.
Installation manual Electric Back-up Heater 6kW 0020152773_06