If The Sauna Heater Will Not Heat Up; Instructions For The Installer; Preparing For Sauna Heater Installation; Installation - Helo CAVA Instalación Y Manual De Uso

Calentador de sauna eléctrico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 88
Installation and User Manual HELO CAVA / HELO ROXX DET

2.5. If the sauna heater will not heat up

If the sauna heater will not heat up, please check that:
- the power is on;
- the main fuses of the sauna heater are intact;
- is there any error messages on the control panel. In case of an error message on the control panel, please refer to the control
panel instructions.

3. Instructions for the installer

THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMISES FOR THE
FUTURE USER.

3.1. Preparing for sauna heater installation

Check the following before installing the sauna heater.
1. The ratio of the heater's input (kW) and the sauna room's volume (m
on page 11. The minimum and maximum volumes must not be exceeded.
2. The sauna room height must be a min. of 1900 mm.
3. Uninsulated and masonry stone walls extend the preheating time. Each square metre of plastered ceiling or wall surface adds
3
1.2 m
to the sauna room's volume.
4. Check page 12 Table 2 for a suitable fuse size (A) and the correct diameter of the power supply cable (mm²) for the sauna
heater in question.
5. Conform to the specified safe clearance around the sauna heater. Please refer to table 1 on page 11.
6. There should be enough room around the sauna heater for maintenance purposes. Also a doorway can be considered as a
maintenance area.

3.2. Installation

Follow the safety clearance specifications on page 11 when installing the sauna heater. A thin panel is not a suitable mounting
base; the mounting base must be reinforced with timber behind the panel. The minimum clearances specified on page 11 must
be followed even if the sauna room wall materials are incombustible.
Walls or ceilings must not be clad with fibre-reinforced plaster board or other light-weight cladding, because they may cause a
fire hazard.
Install the sauna heater so that the sign and the warnings can be read even after the installation.
The control panels are installed outside the sauna room with the exception of the Midi controller which is installed on the wall
beside the sauna heater. Refer to more detailed installation instructions in the installation and operation guide of the control
panel.
Only a single sauna heater is allowed per sauna room

3.1. Connection of the sauna heater to the mains

The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations. The
sauna heater is connected with a semi-permanent connection. Use H07RN-F (60245 IEC 66) cables or a corresponding type.
Other output cables (signal lamp, electric heating toggle) must also adhere to these recommendations. Do not use PVC
insulated cable as a connection cable for the sauna heater.
A multipolar (e.g. 7-pole) cable is allowed, if the voltage is the same. In the absence of a separate control current fuse, the
diameter of all cables must be the same, i.e. in accordance with the front fuse.
The connecting box on the sauna wall should be located within the minimum safety clearance specified for the sauna heater.
The maximum height for the connection box is 500 mm from the floor. See page 12 Image 5 Location for the connecting box.
If the connection box is located at over 500mm distance from the heater, the maximum height is 1000mm from the floor.
3
). Volume recommendations are presented in the table 1
5
Tabla de contenido
loading

Este manual también es adecuado para:

Roxx det

Tabla de contenido