Operating Mode 2: Maxvisio Alone - Sputnik Engineering MaxVisio Documentación Del Dispositivo

El panel de visualización para sus inversores
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Connecting wire
"A"
"B"
"+"
"GND"
4. Feed the cable through the cable bushing in the bottom of the casing and then
refi t the cover.
5. Plug the RJ-45 connector of the connection cable into a free RJ-45 socket at
one end of the MaxComm network.
6. Switch MaxWeb on again. In the MaxVisio menu Settings – Software, select the
option "Operating mode 1" and wait until the device is ready.
7. Within a maximum of two minutes the current system data should appear in
the MaxVisio display.
SolarMax C
SolarMax C
RJ-45
RJ-45
Please note: If your network consists of more than 40 inverters or is
over 300 metres in length, the MaxComm network is unsuitable as a
power supply medium for MaxVisio. In this case, please use the plug-in
power supply unit provided. Connect MaxVisio as follows:
Connecting wire
"A"
"B"
Plug-in power supply wire
"+"
"GND"
25
MaxVisio terminal
"A"
"B"
"V +"
"GND"
230 V
230 V
/ 15 V
AC
AC
DC
SolarMax C
MaxWeb
MaxVisio
RJ-45
RJ-45
V+, GND, A, B
Wiring for operating mode 1
MaxVisio terminal
"A"
"B"
MaxVisio terminal
"V +"
"GND"
Do not connect the "+" and "GND" wires of the connecting cable to the MaxVisio
terminal, and do not remove the insulation from the wires! In addition, please fol-
low the wiring instructions for MaxComm networks as described in the MaxWeb
instructions.

3.2 Operating mode 2: MaxVisio alone

Requirements:
The communication interfaces of the SolarMax inverter and the MaxMeteo ir-
radiance sensor (if present) are linked to one another.
Each device has been assigned a unique network address between 1 and 50.
All devices are running.
Procedure:
1. Remove the lower cover from the MaxVisio display unit casing by applying
pressure to the tab on the right, and then pulling the cover off in a top, left
direction.
2. Remove the insulation from the "+" and "GND" wires of the connecting cable
and connect it to the MaxVisio screw terminal as follows:
Connecting wire
"A"
"B"
"+"
"GND"
Plug-in power supply wire
"+", black
"GND", white
Ensure that the "+" and "GND" wires of the data cable and the plug-in power
supply are fi tted securely in the screw terminal!
3. Feed the cable through the cable bushing in the bottom of the casing and refi t
the cover.
4. Plug the RJ-45 connector of the connection cable into a free RJ-45 socket at
one end of the MaxComm network.
MaxVisio terminal
"A"
"B"
"V +"
"GND"
MaxVisio terminal
"V +"
"GND"
en
26