CodE
PossIBlE CAusE
13
Loose belt
14
Pump or motor mounting nuts are loose
15
Motor overload protection switch has tripped
Loose pulley
16
17
Loose flywheel
18
Carbon build-up in pump
19
Belt to tight
Pulley misalignment
0
1
Extension cord is wrong length or gauge
Loose electrical connections
3
Pump oil is low
PossIBlE solutIon
Check belt tension, see Adjusting Belt tension under
Maintenance.
Torque pump mounting nuts to 6– 8 ft.-lbs. (8.1–10.8 Nm).
Torque
motor
mounting
(11.3– 13.6 Nm). WARNING: Risk of bursting. Excessive
vibration could weaken the air tank and cause it to rupture
or explode. Mounting screws must be kept tightened.
See Motor overload under Features.
Tighten pulley set screw, torque to 145–165 in.-lbs.
(16.4– 19.6 Nm).
Tighten
flywheel
(0.3– 4.4 Nm).
Contact an EmGLO factory service center or an EmGLO
authorized service center.
Check belt tension, see Adjusting Belt tension under
Maintenance.
See
Motor
Pulley/flywheel
Maintenance.
Check for proper gauge wire and cord length. See
Extension Cords under Installation.
Contact an EmGLO factory service center or an EmGLO
authorized service center.
Add EMGLO Synthetic Blue compressor oil to pump. See
Compressor Pump oil under Maintenance.
bolts
to
100– 10 in.-lbs.
screw,
torque
to
15–18
Alignment
ft.-lbs.
under