BASIC SHREDDING OPERATION
PAPER OR CD/CARD
1
Continuous operation:
Up to 12-minutes maximum
NOTE: Shredder runs briefly
after each pass to clear entry.
Plug in and
Continuous operation beyond
turn ON (I)
12-minutes will trigger
25-minute cool down period.
ADvANCED PRODUCT FEATURES
SafeSense
Technology
®
Stops shredding immediately when
hands touch the paper opening.
SAFESENSE
TECHNOLOGY
®
Stops shredding immediately when hands touch the paper opening.
SET-UP AND TESTING
1
2
Turn the shredder ON
Touch test area and
(I) to activate SafeSense
look for the SafeSense
®
indicator to illuminate
For more information about all of Fellowes Advanced Product Features go to www.fellowes.com
PRODUCT MAINTENANCE
OILING SHREDDER
All micro-cut shredders require oil for peak performance. If not oiled, a
machine may experience diminished sheet capacity, intrusive noise when
shredding, and could ultimately stop running. To avoid these problems, we
recommend you oil your shredder each time you empty your waste bin.
FOLLOW OILING PROCEDURE BELOW AND REPEAT TWICE
1
2
*Apply oil across entry
Press and hold forward
( ) 2-3 seconds
* Only use a non-aerosol vegetable oil in long
nozzle container such as Fellowes 35250
Go to Support Section at www.fellowes.com or see back page of manual for useful telephone numbers.
TROUBLESHOOTING
Overheat Indicator: When the Overheat Indicator is illuminated, the shredder has exceeded its maximum operating temperature and needs to cool down. This
indicator will remain illuminated and the shredder will not operate for the duration of the recovery time. See Basic Shredding Operation for more information about
the continuous operation and recovery time for this shredder.
SafeSense
Indicator: If hands are too close to the paper entry, the SafeSense
®
2
3
or
Feed paper/card
Hold CD at edge, feed
straight into paper
into center of entry and
entry and release
release
SilentShred™ Technology
SilentShred™ noise quality
shreds without noisy disruptions.
3
SafeSense
is active and
®
working properly
®
CLEANING AUTO-START INFRARED SENSORS
Paper detection sensors are designed for maintenance free operation. However, on rare occasions the sensors
may become blocked by paper dust causing the motor to run even if there is no paper present.
(Note: two paper detection sensors are located in the center of the paper entry)
TO CLEAN THE SENSORS
1
Turn OFF (O) and
unplug shredder
15
indicator will illuminate and the shredder will stop shredding.
®
4
When finished
shredding set to
OFF (O)
.
2
3
Locate Auto-start
Dip cotton swab in
infared sensor
rubbing alcohol
4
Using cotton swab, wipe
away any contamination
from the paper sensors