Power driver and wiring
•
To allow for variance in the installation, it is not recommended to load the power driver beyond 90% of it's rated maximum power
- Xitanium LED driver 100 W (logistic code 929001430080) max 90 W
- Xitanium LED driver 80 W (logistic code 929000653906) max 72 W
- Xitanium LED driver 20 W (logistic code 929000654006) max 18 W
•
Use Philips InteGrade LED power cable of 1 m (39 inch) or 2.5 m (98 inch)
•
If InteGrade power cables are extended, only use 0.75 mm2 (AWG 18) or thicker cable uptil a length of max 10 m (32 feet) between
driver and Philips LED power cable
•
If you wish to make any other configuration, please contact Philips.
Wiring diagram with Philips InteGrade LED engines
Xitanium LED
Power Driver
24 VDC 80W
driver cable
approx 0.3 m
(12 inch)
To allow for variance in the installation, it is not recommended to load the power driver beyond
90% of it's rated maximum power.
© Philips Lighting Holding B.V. 2018. All rights reserved. Philips reserves
the right to make changes in specifications and/or to discontinue any
product at any time without notice or obligation and will not be liable
for any consequences resulting from the use of this publication.
Document order number: 4422 409 67861
08/2018
Data subject to change
InteGrade LED
InteGrade LED
InteGrade LED
InteGrade LED
InteGrade LED
A
B
0.75 mm
2
Philips LED
(AWG 18)
power cable
max. 10 m
max. 2.5 m
(32 feet)
(98 inch)
www.philips.com/oem
www.philips.com/ledrefrigeration
www.philips.com/ledmodulesna
NA Customer Support/Technical
Service: Tel. (1)800-372-3331