General Information; Ec Declaration Of Conformity - Atlas Copco P2540 Instrucciones De Operación Y Seguridad

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
Safety and operating instructions
4 Explosive atmosphere must not be ignited
To prevent injury and property loss from fires:
• use other technique
• use accessories of non sparking material (e.g.
needle attachment of Beryllium copper for a
needle scaler)
5 Electric chock may be fatal
• avoid chiselling into electric wiring hidden inside
walls etc.
Long term risks when using the machine
6 Always use ear protection
To prevent gradual loss of hearing due to exposure
to high noise levels:
• wear ear protection
7 Vibration may be harmful to hands and
arms
• use vibration dampened tools if available
• reduce the total time of exposure to vibrations,
particularly if the operator has to guide the chisel
by hand
8 Dust generated during operation may be
harmful
• use spot suction or a breathing apparatus
4
EN
© Atlas Copco Industrial Technique AB - 9836 5862 00
Proper use and maintenance
9 Do not perform idle blows with a hammer
• they will cause high internal stresses and shorten
the life of the tool
• note the risk of shooting out the chisel, die or
punch if the retainer is not in order
10 Quick coupling
• if a quick coupling is used on a percussive tool,
it shall be separated from the tool by a whip hose
(length 0.5 m)
11 Maintenance
Good service life and safe function is offered if the
instructions for lubrication, maintenance and over-
haul supplied with the machine are followed.
Use genuine Atlas Copco replacement kits and
parts only.
Warning
Make sure you are familiar with the operating instruc-
tions before you use this machine.
This machine, its attachments and accessories must
only be used for the purpose for which they were
designed:
General chipping, cutting and riveting work (not
for nailing without proper attachments).
For product liability and safety reasons any
modification to the machine, its attachments or ac-
cessories must be agreed in advance with an author-
ized technical representative of the manufacturer.

General information

EC DECLARATION OF CONFORMITY

We, Atlas Copco Industrial Technique AB, S-105
23 STOCKHOLM, SWEDEN declare that the
product (with name, type and serial number, see front
page) is in conformity with the following Direct-
ive(s):
P2540
Tabla de contenido
loading

Este manual también es adecuado para:

8425 0103 40

Tabla de contenido